11.6.23.31 Error 22-38 (emergency code 7305h)
Cause: Channel 1 Initialization, EndDat 2.1: error, 'PositionBits' read from encoder
Suggested steps:
Number of clocks to transmit the position from the encoder. No further information
available. Please contact your service provider.
Initialization encoder
channel
l
This is probably an internal problem of the
encoder!
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
11.6.23.32 Error 22-40 (emergency code 7305h)
Cause: Channel 1 Initialization, Np: error from review of parameters 'Lines' and
'NominalIncrement'
Suggested steps:
Please check this parameters.
Initialization encoder
channel
l
This is probably a problem of the
parameterization!
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
387
11 Alarms & warnings
11.6.23.33 Error 22-41 (emergency code 7300h)
Cause: Channel 1/3 Initialization, EndDat: common error
Suggested steps:
Please note the extended information of the error message
Initialization encoder
channel
l
Error during the initialization routines of
encoder channel.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
11.6.23.34 Error 22-42 (emergency code 7305h)
Cause: Channel 1 Initialization, SSI: common error
Suggested steps:
Please note the extended information of the error message
Initialization encoder
channel 1
l
Error during the initialization routines of
encoder channel 1.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.