The scaling of the units is performed in the motion profile of the standard motor
control. A scaling assistant is available for this purpose (“Scaling / Units” button).
Image 7.93: “Motion profile” screen
Because a volumetric flow rate control underlies the position control, the following
settings must be made beforehand.
The parameter P 2840[8] - QActCalc can be used to select whether the volumetric
flow rate value is to be taken from a sensor (MEAS(0) = From measurement) or, as in
this example, determined by means of a calculation using the cylinder speed and
the pump displacement volume (CYL(1) = From cylinder speed).
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
217
7 Control
Image 7.94: Volumetric flow rate control screen
NOTE
l
The cylinder geometry must be configured for the CYL(1) mode
(
see also section "Cylinder configuration" on page 188
The position controller is a PI controller. The control dynamics can be set using
P 2848 - HYD_PosCon.