11.6.14.10 Error 13-10 (emergency code FF00h)
Cause: Sercos option: Phase switching without ready acknowledge
Suggested steps:
Error during phase switching. Switchover without or with incorrect command
execution. Please check the settings in the master!
The device was probably
disconnected from the
master controller, or the
master is overloaded.
l
Please check the bus system connection. Try
to replace the cables.
l
Please try to reduce computational load on the
master.
l
Try to increase the master cycle time.
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
350
11 Alarms & warnings
11.6.14.11 Error 13-11 (emergency code FF00h)
Cause: Sercos option: Error while parameter initialisation
Suggested steps:
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
11.6.14.12 Error 13-12 (emergency code FF00h)
Cause: Sercos option: Run time error
Suggested steps:
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo drive.