11.6.19.2 Error 18-2 (emergency code 8612h)
Cause: Homing: Limit switch tripped unexpectedly
Suggested steps:
Check home switch
There is a problem with the
digital/analog inputs
l
Please check the 24V I/O wiring, function
assignment and inversion parameters.
l
Please check connected switches for
chattering. Consider using the input filter.
This is possibly an EMC
issue. This is very likely if the
problem occurs when
switching on motor control
and/ or when connecting DC
link power supply.
l
Please check the device cabling for proper
connection.
l
Please check device grounding, i. e. the
connection to a metal backplane and cabinet
connection to earth.
l
Check motor grounding and motor cable
length.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
364
11 Alarms & warnings
11.6.19.3 Error 18-3 (emergency code 8612h)
Cause: Homing: Limit switch error
Suggested steps:
Please check the limit switches.
There is a problem with the
digital/analog inputs
l
Please check the 24V I/O wiring, function
assignment and inversion parameters.
l
Please check connected switches for
chattering. Consider using the input filter.
This is possibly an EMC
issue. This is very likely if the
problem occurs when
switching on motor control
and/ or when connecting DC
link power supply.
l
Please check the device cabling for proper
connection.
l
Please check device grounding, i. e. the
connection to a metal backplane and cabinet
connection to earth.
l
Check motor grounding and motor cable
length.
11.6.19.4 Error 18-4 (emergency code FF00h)
Cause: Homing: Wrong homing method, homing method not available
Suggested steps:
l
Please restart the application (24V reset).
l
If the error is still reported after the restart please contact your service partner.
An error occured at the
homing methode.
l
Please acknowledge the error.
l
Please start the homing method again.