11.6.34.7 Error 35-6 (emergency code 7307h)
Cause: ENC CH3 SSI: error, encoder monitoring
Suggested steps:
Check encoder cables, voltage supply, and selection. Make sure unused channels
are switched off.
The encoder is not
connected or not working
properly.
l
If this is encoder has analog signals, please
check the signal amplitude vs. parameter
EncObsMin
l
Check cabling. If available, please try another
encoder and cable.
l
See detailed error information (>>) for a more
detailed description.
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
410
11 Alarms & warnings
11.6.34.8 Error 35-7 (emergency code 7307h)
Cause: ENC CH3 SSI: error, parity error
Suggested steps:
Check encoder cables, voltage supply, and selection. Make sure unused channels
are switched off.
The encoder is not
connected or not working
properly.
l
If this is encoder has analog signals, please
check the signal amplitude vs. parameter
EncObsMin
l
Check cabling. If available, please try another
encoder and cable.
l
See detailed error information (>>) for a more
detailed description.
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.