Chapter 13 Control Sub Functions
[4] When the hardware stroke limit function is not used
When not using the hardware stroke limit function, set the logic of FLS and RLS
to the "negative logic" (initial value) with "[Pr.22] Input signal logic selection" and
input the signal which always turns ON. Otherwise, set the logic of FLS and RLS
to the "positive logic" with "[Pr.22] Input signal logic selection" and always turn
OFF the input.
[5] Servo parameter setting [CiA402 mode]
Set "Sensor input type selection" of the servo parameter "Function selection D-4
(PD41)" properly at MR-J4-GF use. Otherwise, the stroke limit signal cannot be
released. The operation at stroke limit detection according to each setting is as
follows.
Control
details
Controller setting
[Pr.80] External input signal
selection
Servo parameter setting
Sensor input type selection of
Function selection D-4 (PD41)
Actual signal
input
Stop process
Other than
HPR
1: External input signal of
servo amplifier
0: Input from servo amplifier
Servo amplifier
–
*1
Controller
*3
1: Input from controller
Servo amplifier
–
*1
2: Buffer memory of
QD77GF
0: Input from servo amplifier
Servo amplifier
–
*1
Controller
–
*1
1: Input from controller
Servo amplifier
–
*2
Controller Controller
HPR
1: External input signal of
servo amplifier
0: Input from servo amplifier
Servo amplifier
Servo amplifier
1: Input from controller
Servo amplifier
–
*1
2: Buffer memory of
QD77GF
0: Input from servo amplifier
Servo amplifier
–
*1
Controller
–
*1
1: Input from controller
Servo amplifier
–
*2
Controller Servo
amplifier
1 : The error "Servo parameter PD41 setting error" (error code: 1005) occurs. The cyclic transmission is not
performed.
2 : The stroke limit signal cannot be released.
3 : When "1: Enabled only for HPR mode" is set to "Stroke limit enabling condition selection" of the servo
parameter "Function selection D-4 (PD41)"
POINT
The consistency between "[Pr.80] External input signal selection" and the servo
parameter "Function selection D-4 (PD41)" is checked at the start of connection
with the servo amplifier. At the diagnostic error, the error "Servo parameter PD41
setting error" (error code: 1005) occurs and the cyclic transmission with the servo
amplifier of the target axis is not performed.
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......