Chapter 9 Major Positioning Control
(2) Set JUMP instruction to positioning data No. that "continuous positioning
control" or "continuous path control" is set in operation pattern.
It cannot set to positioning data No. that "positioning complete" is set in
operation pattern.
(3) Positioning control such as loops cannot be executed by conditional JUMP
instructions alone until the conditions have been established.
When loop control is executed using JUMP instruction, an axis operation
status is "analyzing" during loop control, and the positioning data analysis
(start) for other axes are not executed. As the target of the JUMP instruction,
specify a positioning data that is controlled by other than JUMP and NOP
instructions.
Positioning data setting example
[When "JUMP instruction" is set in positioning data No. 1 of axis 1]
Setting item
Setting example
Setting details
Axis 1
Pos
itioning d
ata N
o. 1
[Da.1] Operation pattern
–
Setting not required. (Setting value is ignored.)
[Da.2]
Control method
JUMP instruction
Set the JUMP instruction.
[Da.3]
Acceleration time No.
–
Setting not required. (Setting value is ignored.)
[Da.4]
Deceleration time No.
–
[Da.6]
Positioning address/
movement amount
–
[Da.7]
Arc address
–
[Da.8]
Command speed
–
[Da.9]
Dwell time/JUMP
destination positioning
data No.
500
Set the positioning data No. 1 to 600 for the JUMP
destination. (The positioning data No. of the JUMP
instruction cannot be set. Setting its own positioning data No.
will result in the error "Illegal data No." (error code: 502).)
[Da.10]
M code/Condition
data No./Number of
LOOP to LEND
repetitions
1
Set the JUMP instruction execution conditions with the
condition data No.
0 :
Unconditional
JUMP
1 to 10 : Condition data No.
("Simultaneous start" condition data cannot be
set.)
[Da.20]
Axis to be interpolated
No.1
–
Setting not required (setting value is ignored).
[Da.21]
Axis to be interpolated
No.2
–
[Da.22]
Axis to be interpolated
No.3
–
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......