16 - 10
Chapter 16 Troubleshooting
Warning storage
(1) When an axis warning occurs, the warning code corresponding to the warning
details is stored in the following buffer memory ([Md.24] Axis warning No.) for
axis warning No. storage.
Axis No.
Buffer memory address
1 2407
2 2507
3 2607
4 2707
5 2807
to to
16 3907
A new warning code is stored in the buffer memory address ([Md.24] Axis
warning No.) for axis warning storage every time a warning occurs.
(2) When an axis warning occurs in a positioning operation, etc., "axis warning
detection ([Md.31] Status: b9)" of the following buffer memory for axis status
storage turns ON.
Axis No.
Buffer memory address
1 2417
2 2517
3 2617
4 2717
5 2817
to to
16 3917
When a warning occurs on servo amplifier, the warning "Servo amplifier
warning" (warning code: 2000) is stored in "[Md.24] Axis warning No.", and the
warning code of servo amplifier is stored in the following buffer memory
address ([Md.114] Servo alarm). Check the warning details and remedies by
this servo alarm details.
Axis No.
Buffer memory address
1 2488
2 2588
3 2688
4 2788
5 2888
to to
16 3988
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......