2 - 3
Chapter 2 System Configuration
2.2 Component list
The positioning system using the QD77GF is configured of the following devices.
No. Part
name
Type
Remarks
1
Simple Motion
module
QD77GF4
GF: CC-Link IE Field Network
QD77GF
Number of control axes
QD77GF8
QD77GF16
2 Personal
computer
Personal
computer which
supports
Windows
R
(Prepared by user)
Refer to the "GX Works2 Version1 Operating Manual (Common)" for details.
3 RS-232
cable
QC30R2
(Prepared by user)
An RS-232 cable is needed for connecting the CPU module with a personal
computer.
Refer to the "GX Works2 Version1 Operating Manual (Common)" for details.
4 USB
cable
–
(Prepared by user)
A USB cable is needed for connecting the CPU module with a personal
computer.
Refer to the "GX Works2 Version1 Operating Manual (Common)" for details.
5 Ethernet
cable
–
(Prepared by user)
An Ethernet cable is needed for connecting the CPU module with a personal
computer. Refer to the "GX Works2 Version1 Operating Manual (Common)"
for details.
6 Servo
amplifier
–
(Prepared by user)
7 I/O
device
–
(Prepared by user)
8
Manual pulse
generator
–
(Prepared by user)
Recommended: MR-HDP01 (Manufactured by Mitsubishi Electric
Corporation)
9
CC-Link IE Field
Network cable
(Note-1)
–
(Prepared by user)
An Ethernet cable is needed for connecting the Simple Motion module with a
servo amplifier and an I/O device.
10
External input signal
cable
(Note-2)
–
(Prepared by user)
Cables are needed for connecting the Simple Motion module with an external
device.
11 Hub
(Note-1)
–
(Prepared by user)
Switching hubs are needed for connecting the Simple Motion module with a
servo amplifier and an I/O device in star topology.
Recommended: DT135TX (Mitsubishi Electric System & Service Co., Ltd.)
(Note-1): Refer to the "MELSEC-Q QD77GF Simple Motion Module User's Manual (Network)" for details of cables and hubs.
(Note-2): The external input wiring connector has been prepared.
[External input wiring connector]
Part name
Specification
Applicable connector
LD77MHIOCON
Applicable wire size
AWG30 to AWG24 (0.05 to 0.2mm
2
)
(Note-3)
(Note-3): AWG24 (0.2mm
2
) is recommended.
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......