13 - 69
Chapter 13 Control Sub Functions
13.7 Other functions
Other functions include the "step function", "skip function", "M code output function",
"teaching function", "command in-position function", "acceleration/deceleration
processing function", "pre-reading start function", "deceleration start flag function",
"stop command processing for deceleration stop function", "follow up processing
function", "speed control 10 multiplier setting for degree axis function" and
"operation setting for incompletion of HPR function". Each function is executed by
parameter setting or sequence program creation and writing.
13.7.1 Step function
The "step function" is used to confirm each operation of the positioning control one by
one.
It is used in debugging work for major positioning control, etc.
A positioning operation in which a "step function" is used is called a "step operation".
In step operations, the timing for stopping the control can be set. (This is called the
"step mode".) Control stopped by a step operation can be continued by setting "step
continues (to continue the control)" in the "step start information".
The details shown below explain about the "step function".
[1] Relation between the step function and various controls
[2] Step mode
[3] Step start information
[4] Using the step operation
[5] Control details
[6] Precautions during control
[7] Step function settings
[1] Relation between the step function and various controls
The following table shows the relation between the "step function" and various
controls.
Control type
Step function
Step applicability
HPR control
Machine HPR control
Step operation not possible
Fast HPR control
Major positioning
control
Position
control
1-axis linear control
Step operation possible
2 to 4-axes linear interpolation control
1-axis fixed-feed control
2 to 4- axes fixed-feed control
(interpolation)
2-axis circular interpolation control
1 to 4- axes Speed control
Step operation not possible
Speed-position switching control
Position-speed switching control
Step operation possible
Other
control
Current value changing
JUMP instruction, NOP instruction,
LOOP to LEND
Step operation not possible
Manual control
JOG operation, Inching operation
Manual pulse generator operation
Expansion
control
Speed-torque control
: Set when required
: Setting not possible
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......