6 - 56
Chapter 6 Sequence Program Used for Positioning Control
6.5.3 Start program
This program is used to start the control with start commands.
The control can be started with the following two methods.
[1] Starting by inputting positioning start signal
[2] Starting by inputting external command signal
PLC CPU
Buffer memory
4300
Input/output signal
1
1)
ON
2)
Y10
Servo amplifier
Control with
positioning data
No. 1
3)
Note) When starting positioning with the scan
after the completion of positioning,
insert the start complete signal ( Md. 31
Status:b14) as an interlock so that
positioning is started after Y10 is turned
OFF and the start complete signal ( Md. 31
Status:b14) is turned OFF.
Simple Motion module
1) Set the "positioning start No." in "[Cd.3] Positioning start No." according to the control to
be started.
(In the above example, set positioning data No. "1".)
2) Input the positioning start signal [Y10] or the external command signal.
3) The positioning data No. "1" will start.
Fig. 6.2 Procedures for starting control (for axis 1)
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......