16 - 36
Chapter 16 Troubleshooting
Classification
of errors
Error
code
Error name
Error
Operation status at error occurrence
Parameter
setting range
errors
953
Deceleration time 1
setting error
The set value of the detailed parameter 2
"Deceleration time 1" is outside the setting
range.
When the PLC READY signal [Y0] is turned
from OFF to ON :The READY signal [X0] is
not turned ON.
At start
: The system does not start.
During operation : The system stops with the
setting (deceleration
stop/rapid stop) of the
detailed parameter 2 rapid
stop selection
(stop group 3).
(Note that the deceleration
stop only occurs during the
manual pulse generator
operation.)
954
Deceleration time 2
setting error
The set value of the detailed parameter 2
"Deceleration time 2" is outside the setting
range.
955
Deceleration time 3
setting error
The set value of the detailed parameter 2
"Deceleration time 3" is outside the setting
range.
956
JOG speed limit value
error
• The set value of the detailed parameter 2
"JOG speed limit value" is outside the
setting range.
• The set value of the detailed parameter 2
"JOG speed limit value" exceeds the
speed limit.
957
JOG acceleration time
selection setting error
The set value of the detailed parameter 2
"JOG operation acceleration time selection"
is outside the setting range.
958
JOG deceleration time
selection setting error
The set value of the detailed parameter 2
"JOG operation deceleration time selection"
is outside the setting range.
959
Acceleration/
deceleration process
selection setting error
The set value of the detailed parameter 2
"Acceleration/deceleration process
selection" is outside the setting range.
960
S-curve ratio setting
error
The set value of the detailed parameter 2
"S-curve ratio" is outside the setting range.
961
Illegal rapid stop
deceleration time
The set value of the detailed parameter 2
"Rapid stop deceleration time" is outside
the setting range.
962
Stop group 1 rapid stop
selection error
The set value of the detailed parameter 2
"Stop group 1 rapid stop selection" is
outside the setting range.
963
Stop group 2 rapid stop
selection error
The set value of the detailed parameter 2
"Stop group 2 rapid stop selection" is
outside the setting range.
964
Stop group 3 rapid stop
selection error
The set value of the detailed parameter 2
"Stop group 3 rapid stop selection" is
outside the setting range.
966
Outside allowance
circular interpolation
error width
The set value of the detailed parameter 2
"Allowance circular interpolation error
width" is outside the setting range.
967
External command
function selection error
The set value of the detailed parameter 2
"External command function selection" is
outside the setting range.
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......