9 - 35
Chapter 9 Major Positioning Control
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning operation.
If the movement amount of each axis exceeds "1073741824 (=2
30
)" when "0:
Composite speed" is set in "[Pr.20] Interpolation speed designation method"
The error "Outside linear movement amount range" (error code: 504) occurs at a
positioning start.
(The maximum movement amount that can be set in "[Da.6] Positioning
address/movement amount" is "1073741824 (=2
30
)".)
Positioning data setting example
[When "2-axis linear interpolation control (INC linear 2)" is set in positioning data
No. 1 of axis 1]
• Reference axis ............. Axis 1
• Interpolation axis.......... Axis 2 (The required values are also set in positioning
data No. 1 of axis 2.)
Axis
Setting item
Setting example
Setting details
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
A
xi
s 1
P
os
iti
oni
ng dat
a No.
1
[Da.1]
Operation pattern
Positioning
complete
–
Set "Positioning complete" assuming the next
positioning data will not be executed.
[Da.2]
Control method
INC linear 2
–
Set incremental system 2-axis linear
interpolation control.
[Da.3]
Acceleration time No.
1
–
Designate the value set in "[Pr.25]
Acceleration time 1" as the acceleration time
at start.
[Da.4]
Deceleration time No.
0
–
Designate the value set in "[Pr.10]
Deceleration time 0" as the deceleration time
at deceleration.
[Da.6]
Positioning address/
movement amount
9000.0
m -3000.0
m
Set the movement amount. (Assuming "mm" is
set in "[Pr.1] Unit setting".)
[Da.7]
Arc address
–
–
Setting not required (setting value is ignored).
[Da.8]
Command speed
6000.00
mm/min
–
Set the speed during movement.
[Da.9]
Dwell time/JUMP
destination positioning
data No.
500ms –
Set the time the machine dwells after the
positioning stop (command stop) to the output
of the positioning complete signal.
[Da.10]
M code/Condition data
No./Number of LOOP
to LEND repetitions
10 –
Set this when other sub operation commands
are issued in combination with the No.1
positioning data.
[Da.20]
Axis to be interpolated
No.1
Axis 2
–
Set the axis to be interpolated.
If the self-axis is set, an error will occur.
[Da.21]
Axis to be interpolated
No.2
– –
Setting not required (setting value is ignored).
[Da.22]
Axis to be interpolated
No.3
– –
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......