5 - 135
Chapter 5 Data Used for Positioning Control
Setting value
Default
value
Buffer memory address
Set with a decimal.
Setting
value
Positioning data No.
1 to 600
7000 to7004
9001
9002
9003
9004
K
: Positioning data No.
: Block start designation
: Machine HPR
: Fast-HPR
: Current value changing
: Simultaneous starting of multiple axes
0 4300+100n
Set with a decimal.
Setting
value
K
Positioning starting point No.
The Simple Motion module resets the value to "0" automatically when the
continuous operation is interrupted.
1 to 50
0 4301+100n
Set with a decimal.
K 1
Error reset request
Setting value
The Simple Motion module resets the value to "0" automatically after the axis
error reset is completed. (Indicates that the axis error reset is completed.)
1: Axis error is reset.
0 4302+100n
Set with a decimal.
K
1
Restart command
Setting value
The Simple Motion module resets the value to "0" automatically after restart
acceptance is completed. (Indicates that the restart acceptance is completed.)
1: Restarts
0 4303+100n
n: Axis No.-1
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......