5 - 112
Chapter 5 Data Used for Positioning Control
Storage item
Storage details
[Md.32] Target value
This area stores the target value ([Da.6] Positioning address/movement amount)
for a positioning operation.
At the beginning of positioning control and current value changing:
Stores the value of "[Da.6] Positioning address/movement amount".
At the HP shift operation of HPR control: Stores the value of HP shift amount.
At other times
: Stores "0".
Refresh cycle: Immediate
[Md.33] Target speed
During operation with positioning data
: The actual target speed, considering
the override and speed limit value,
etc., is stored. "0" is stored when
positioning is completed.
During interpolation of position control
: The composite speed or reference
axis speed is stored in the reference
axis address, and "0" is stored in the
interpolation axis address.
During interpolation of speed control
: The target speeds of each axis are
stored in the monitor of the reference
axis and interpolation axis.
During JOG operation
: The actual target speed, considering
the JOG speed limit value for the
JOG speed, is stored.
During manual pulse generator operation : "0" is stored.
Refresh cycle: Immediate
POINT
The target speed is when an override is made to the command speed.
When the speed limit value is overridden, the target speed is restricted to the
speed limit value. The target speed changes every time data is switched, but
does not change in an acceleration/deceleration state inside each piece of data
(changes with the speed change because the target speed changes.)
[Md.34] Movement amount after
proximity dog ON
[RJ010 mode]
"0" is stored when machine HPR starts.
After machine HPR starts, the movement amount from the proximity dog ON to
the machine HPR completion is stored.
(Movement amount: Movement amount to machine HPR completion using
proximity dog ON as "0".)
Refresh cycle: Immediate
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......