9 - 99
Chapter 9 Major Positioning Control
9.2.17 Speed-position switching control (ABS mode)
In case of "speed-position switching control (ABS mode)" ("[Da.2] Control method" =
Forward run: speed/position, Reverse run: speed/position), the pulses of the speed set
in "[Da.8] Command speed" are kept output in the axial direction set to the positioning
data. When the "speed-position switching signal" is input, position control to the
address set in "[Da.6] Positioning address/movement amount" is exercised.
"Speed-position switching control (ABS mode)" is available in two different types:
"forward run: speed/position" which starts the axis in the forward run direction and
"reverse run: speed/position" which starts the axis in the reverse run direction.
"Speed-position switching control (ABS mode)" is valid only when "[Pr.1] Unit setting"
is "2: degree".
[Pr.1] Unit setting
Speed-position
function selection
mm inch
degree
PLS
INC mode
ABS mode
: Setting allowed,
: Setting disallowed (If setting is made, the error "Speed-position function selection error" (error
code: 935) will occur when the PLC READY signal [Y0] turns ON.)
Use the detailed parameter 1 "[Pr.81] Speed-position function selection" to choose
"speed-position switching control (ABS mode)".
Setting item
Setting
value
Setting details
Buffer memory address
[Pr.81]
Speed-
position
function
selection
2
Speed-position switching control
(ABS mode)
34+150n
(Note): If the set value is other than 0 and 2, it is regarded as 0 and operation is performed in the
INC mode.
For details of the setting, refer to Section 5.2 "List of parameters".
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......