13 - 102
Chapter 13 Control Sub Functions
13.7.10 Speed control 10 x multiplier setting for degree axis function
The "Speed control 10 x multiplier setting for degree axis function" is provided to
execute the positioning control by 10 x speed of the setting value in the command
speed and the speed limit value when the setting unit is "degree".
This section explains the "speed control 10 multiplier specifying function for degree
axis" as follows:
[1] Control details
[2] Setting method of "Speed control 10 x multiplier setting for degree axis function"
[1] Control details
When "Speed control 10 multiplier specifying function for degree axis" is valid,
this function related to the command speed, monitor data, speed limit value, is
shown below.
(1) Command speed
(a) Parameters
"[Pr.7] Bias speed at start"
"[Pr.46] HPR speed"
"[Pr.47] Creep speed"
"[Cd.14] New speed value"
"[Cd.17] JOG speed"
"[Cd.25] Position-speed switching control speed change register"
"[Cd.28] Target position change value (New speed)"
"[Cd.140] Command speed at speed control mode"
"[Da.8] Command speed"
(b) Major positioning control
1) For "2 to 4 axis linear interpolation control" and "2 to 4 axis fixed-feed
control", the positioning control is performed at decuple speed of
command speed, when "[Pr.83] Speed control 10 x multiplier setting for
degree axis" of reference axis is valid.
2) For "2 to 4 axis speed control", "[Pr.83] Speed control 10 x multiplier
setting for degree axis" is evaluated whether it is valid for each axis.
If valid, the positioning control will be performed at decuple speed of
command speed.
Summary of Contents for MELSEC Q Series
Page 2: ......
Page 30: ...A 28 MEMO ...
Page 32: ...MEMO ...
Page 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Page 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Page 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Page 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 376: ...MEMO ...
Page 400: ...8 24 Chapter 8 HPR Control MEMO ...
Page 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Page 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Page 586: ...11 32 Chapter 11 Manual Control MEMO ...
Page 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Page 830: ...Appendix 30 Appendices MEMO ...
Page 833: ......