MAC215986
478
Revision A
1032603
A
A
A
B
C
Figure 4.406: Vertical Knife
–
Guard Removed
8.
Remove three bolts (A) securing milling bar (B) to the blade
bracket and knife section assembly (C). Tilt milling bar (B)
upwards and slide assembly (C) out.
D
F
D
G
A
B
H
1032606
A
C
E
C
Figure 4.407: Vertical Knife
–
Guard Removed
NOTE:
If you cannot tilt milling bar (A) upwards enough to slide
knife section assembly (B) out, remove two bolts (C)
attaching hood (D) to the vertical knife assembly. Loosen
two nuts (E) to loosen slide rail (F). Milling bar (A) should
now be loose enough to tilt upwards.
IMPORTANT:
You should not need to loosen clip hardware (G) and
clips (H) to slide the knife section assembly out. If you need
to loosen this hardware, make sure to tighten the hardware
properly by following Step
during
reinstallation. Overtightening can cause the motor to
overheat, melt plastic components, and burn out. Under-
tightening can cause debris to plug the knives.