MAC215986
207
Revision A
1
2
3
4
5
6 7
8
ϭϬϯϴϵϱϳ
A
B
Figure 3.300: Left Float Indicator
–
View from Rear
8.
Locate connector P600 (A) at the left front of the float
module.
9.
Remove plug cap (B).
10. Turn the key to the run position.
11. Check P600 for power from the combine. There should be
5V at pin 7.
•
Pin 7 - FM2215E
–
power
•
Pin 8 - FM2515E
–
ground
12. On connector P600, confirm upper voltage from left sensor
(pins 1 and 8), and right sensor (pins 3 and 8).
For voltage, Refer to
3.10.2 Sensor Output Voltage Range
Combine Requirements, page 205
•
Pin 1 - FM3326A
–
left sensor signal
•
Pin 3 - FM3328A
–
right sensor signal
•
Pin 8 - FM2515E
–
ground
NOTE:
If the standard plug is installed in P600, the plug sends the
average of both sensors to the combine. If the optional
lateral tilt plug is installed, then the plug sends separate
voltage signals from both sensors to the combine.
Checking sensor lower voltage limit
1031986
A
Figure 3.301: Center-Link
13. Extend the guard angle until header angle indicator (A) is
at
E
.