MAC215986
397
Revision A
1013299
B
A
C
Figure 4.235: Pan and Deflector Distance
4.
Adjust deflector (A) so that distance (C) between the pan
and the deflector is 4
–
6 mm (5/32
–
1/4 in.).
5.
Tighten nuts (B).
6.
Repeat the previous steps for the opposite deflector.
7.
Attach the header to the combine. For instructions, refer
to Chapter
3.6 Header Attachment/Detachment, page 52
8.
After attaching the header to the combine, fully extend the
center-link and check the gap between the deflector and
pan. Maintain the 4
–
6 mm (5/32
–
1/4 in.) gap.