MAC215986
232
Revision A
1035156
A
Figure 3.351: New Holland Combine Display
6.
If the statement
“
Confirm varifeed knife is completely
retracted
”
(A) appears, press ENTER. The varifeed knife is
not applicable to MacDon headers.
1035158
A
Figure 3.352: New Holland Combine Display
7.
Follow the calibration steps (A) in the order in which they
appear on the page. As you proceed through the calibration
process, the display will automatically update to show the
next step.
NOTE:
Pressing the ESC key during any of the steps or letting the
system sit idle for more than 3 minutes will cause the
calibration procedure to stop.
NOTE:
Refer to your combine operator
’
s manual for an
explanation of any error codes.
8.
When all steps have been completed, CALIBRATION
COMPLETED message is displayed on the page.
Checking Reel Height Sensor Voltages
–
New Holland CR Series
Check the reel height sensor voltages to ensure they are within the prescribed range.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for the most up-to-date information.
1016049
A
Figure 3.353: New Holland Combine Display
1.
On the main page of the combine display, select
DIAGNOSTICS (A). The DIAGNOSTICS page opens.