![MacDon CASE IH FlexDraper FD225 Manual Download Page 134](http://html.mh-extra.com/html/macdon/case-ih-flexdraper-fd225/case-ih-flexdraper-fd225_manual_685656134.webp)
MAC215986
110
Revision A
Installing Additional Bolt-On Flighting
–
Ultra Narrow Configuration Only
When converting the feed auger to Ultra Narrow configuration, some hole drilling is required to install additional flighting.
A
A
1034023
Figure 3.122: Narrow Configuration
NOTE:
This procedure assumes the feed auger is currently in Narrow
configuration (4 long flightings [A] installed).
To install the four additional long flightings for Ultra Narrow configuration, follow these steps:
1.
To improve access to the feed auger and ease installation, remove the float module from the combine.
1034011
A
B
C
Figure 3.123: Left Side of Auger
2.
Rotate the auger as needed.
NOTE:
The illustrations in this procedure show the feed auger
separated from the float module for clarity. This procedure
can be performed with the feed auger installed in the float
module.
3.
Place new flighting (A) outboard of existing flighting (B) on
the left side of the auger, as shown.
4.
Mark hole locations (C) onto existing flighting (B).
5.
Remove nearest access cover to existing flighting (B). Retain
the hardware for reassembly.
6.
Remove existing bolt-on flighting (B) from the auger. Retain
the hardware for reassembly.