background image

MAGNA

User Manual 

Operating Microscope Dentistry

Part No.: 6129000-795
Issue 1.7
Printed on May,2020

To ensure proper use of this instrument as well as to avoid injury while operating instrument, 
Understanding this manual completely before use is highly recommended.

Summary of Contents for Magna

Page 1: ...roscope Dentistry Part No 6129000 795 Issue 1 7 Printed on May 2020 To ensure proper use of this instrument as well as to avoid injury while operating instrument Understanding this manual completely b...

Page 2: ...to change without prior notice LABOMED reserve the right to make changes to the product described in this user manual without notice and without incorporating those changes in any products already so...

Page 3: ...ng Ceiling Mount On Concrete Ceilings Product Description Wall Mount Wall Mount Installation Wall Mount Installation Procedure Wall Mount Installation on Wooden Wall Wall Mount Installation on Masonry...

Page 4: ...m that enables the ultimate flexibility in maneuvering the microscope s viewing angle and position 5 The Labomed NuVar CMO with variable working distance objective comes standard and provides user gre...

Page 5: ...ABA Arm 22 Left Hand Release Electromagnetic Clutch 23 Wire Mesh 24 Fibre Light Guide 25 Filter Change knob 1 Caster wheel with Brakes 2 Cross Base Top 3 Cross Base Bottom 4 Column 5 Hand Rest 6 Swiv...

Page 6: ...tic Clutch 8 Illumination Control knob 9 Ergo Head 0 210 adjustable 10 Eyepieces 11 Right Hand Release Electromagnetic Clutch 12 Zoom Magnification Knob 13 Common Main Objective with Fine Focusing 14...

Page 7: ...9000 795 Magna 4 Issue 1 7 Printed on May 2020 4 INSTALLATION REFERENCES CEILING MOUNT CEILING MOUNT SYSTEM FOR 12 FEET CEILING HEIGHT 1064 500 1000 150 2309 3660 12 1351 4 43 3 6 0 310 360 220 170mm...

Page 8: ...29000 795 Magna 5 Issue 1 7 Printed on May 2020 INSTALLATION REFERENCES CEILING MOUNT CEILING MOUNT SYSTEM FOR 11 FEET CEILING HEIGHT 1064 500 1000 150 2309 3352 11 1043 3 42 3 6 0 310 360 220 170mm F...

Page 9: ...129000 795 Magna 6 Issue 1 7 Printed on May 2020 INSTALLATION REFERENCES CEILING MOUNT CEILING MOUNT SYSTEM FOR 10 FEET CEILING HEIGHT 1064 500 1000 150 2309 3050 10 741 2 4 3 6 0 310 360 220 170mm Fi...

Page 10: ...ng References Issue 1 7 Printed on May 2020 Magna INSTALLATION REFERENCES CEILING MOUNT Master Plate Spacer Ceiling Mount Column 168MM 175mm 175mm 175mm 175mm 175mm 175mm 175mm 175mm 400mm 400mm Figur...

Page 11: ...NA 6129000 795 Magna 8 Issue 1 7 Printed on May 2020 INSTALLATION REFERENCES CEILING MOUNT Operator Position Patient is right below the microscope optical head R1800mm 1 3 8 5 3 m m 694mm 1199mm Figur...

Page 12: ...MAGNA 6129000 795 Magna 9 Issue 1 7 Printed on May 2020 INSTALLATION REFERENCES CEILING MOUNT Operator Position Patient is right below the microscope optical head 694mm 1198mm Figure 9...

Page 13: ...sing the Paper template provided mark the positions of the six 6 mounting holes on wooden membrane refering figure 4 Drill six 6 1 4 6mm pilot holes either direct into Joist or the additional wooden m...

Page 14: ...5 11 Issue 1 7 Printed on May 2020 Wooden membrane Heavy Duty vibration free Ceiling Mount Joist Master Plate Shim Column Level Joist Master Plate Shim Column Level Normal Ceiling Mount Wooden membran...

Page 15: ...he bottom of ceiling mount as shown in Figure and to check the Vertical leveling Use Shims as required and adjust the RAWL Bolts Lag bolts until the column is Vertical 3 Tighten all screws securely NO...

Page 16: ...ount Provided against the master plate and insert 6 socket head bolts M12 X 40 after aligning the 6 mounting holes 7 Tighten all the bolts using Allen key 10mm slightly 8 Use a level to ensure the col...

Page 17: ...late 10 pcs Threaded Spacer 12 pcs M10x40 Socket Head Cap Screw 4pcs M6x10 Socket Set Screw 3pcs RAVAL PLUG M10x75mm SS 854 8 NOS TO BE FIXED IN CONCRETE CEILING BOLT M1Ox75mm SS 854 8 NOS FIXED IN RA...

Page 18: ...Suspension Arm 5 Suspension Arm Hydraulic Movement Lock Knob 6 Auto Balancing Arm Lock Knob 7 ABA Auto Balancing Arm Magnetic Clutch 8 Illumination Control knob 9 Ergo Head 0 210 adjustable 10 Eyepiec...

Page 19: ...MAGNA INSTALLATION REFERENCES WALL MOUNT Operator Position Patient is right below the microscope optical head Magna 6129000 795 16 Issue 1 7 Printed on May 2020 Figure 19...

Page 20: ...A INSTALLATION REFERENCES WALL MOUNT Rotation of Suspension Arm about the Horizontal Arm on both the Ceiling Mount and the floor stand is 360 Rotation of Horizontal Arm about the Column on the Wall Mo...

Page 21: ...WALL MOUNT 6 COUNTER HOLE 16mm x 2 0mm DEEP THRU HOLE 11 0mm 406mm 2267mm 125mm 125 500mm 600mm 346mm 2542mm 2242mm 250mm 1232mm 750mm 150mm 1063mm 2 4 0 310 220 360 6 COUNTER HOLE 16mm x 2 0mm DEEP...

Page 22: ...Wall mount MARKING REFERENCE Anchoring the Wall mount Reference A Paper Template for marking B Wall Mount Assembly C Distance from Floor Refer suitable height as per ordered configuration from figure...

Page 23: ...nchor Bolts for Masonry walls 6 6 Cap set bolt 6 WALL MOUNT INSTALLATION Before Initiating the installation of Labomed Wall Mount Microscopes You must ensure that there is proper space available as pe...

Page 24: ...Magna MAGNA 6129000 795 21 Issue 1 7 Printed on May 2020 7A WALL MOUNT INSTALLATION FOR WOODEN WALL 6NOS WASHER 6 NOS HEX HEADWOODEN SCREW 10x100 CAP RAWAL PLUG M10 PART NO SS 855 6 NOS Figure 25...

Page 25: ...ue 1 7 Printed on May 2020 7B WALL MOUNT INSTALLATION FOR SOLID BRICK WALL WASHER 6 NOS CAP RAVAL PLUG M10 SS 855 6 NOS BOLT M1Ox75mm SS 854 6 NOS FIXED IN RAVAL PLUG RAVAL PLUG M10x75mm SS 854 6 NOS...

Page 26: ...MM WOODEN WALL STUD SPACING For securing the Wall Mount System to construction using wooden wall studs spaced on 16 406 mm Inch centers it is recommended that 3 8 x 4 hex head lag screws are used WARN...

Page 27: ...et to slightly loosen the 3 8 x 4 hex head lag screws in the corners of the back plate 4 Adjust the back plate until it is level and tighten the three lag screws on the bottom leaving the top lag scre...

Page 28: ...ep in the wall spaced as Outlined above 4 Use 10mm X 75mm long RAWL Anchor bolts 5 Place the RAWL bolts through the holes and carefully insert the bolts into the wall 6 Take out the threaded bolt 7 Po...

Page 29: ...Magna MAGNA 6129000 795 26 Issue 1 7 Printed on May 2020 Shim Level Wall Mount Assembly Figure 30...

Page 30: ...dic ular to the floor See figure 13 6 If the back plate is not perpendicular insert shim material between the back plate and the wall next to the RAWL bolts Check with the level and tighten the toggle...

Page 31: ...be taken into consideration when calculating the effective strength Specification of the bolt anchor manufacture Quality of the structural roof e g the strengths and the thickness of the concrete Spac...

Page 32: ...ERATOR OR PATIENT MAY OCCUR WARNING IF THIS INSTRUMENT IS MODIFIED APPROPRIATE INSPECTION AND TESTING MUST BE CONDUCTED TO ENSURE CONTINUED SAFE USE OF THIS INSTRUMENT WARNING TO AVOID RISK OF ELECTRI...

Page 33: ...IPMENT CAN AFFECT MEDICAL ELECTRICAL EQUIPMENT CAUTION THIS INSTRUMENT IS NOT TO BE USED NEAR HIGH FREQUENCY EMITTING SURGICAL EQUIPMENT CAUTION DO NOT CONNECT ANY EQUIPMENT TO THE DEVICE OTHER THAN T...

Page 34: ...anying documents must be consulted Compliance to medical device directive 93 42 EEC Suspension Arm Locking This way up indicates the correct upright position of the transport package Keep dry the tran...

Page 35: ...etermination of field of view and direction of view of endoscopes with optics ISO 8600 5 First edition 2005 03 15 Optics and photonics Medical endoscopes and endotherapy devices Part 5 Determination o...

Page 36: ...r Wall Ceiling 3 Swivel arm and suspension arm assembly with fiber optic cable Depending upon type of mounting Floor or Wall Ceiling 4 Auto Balancing Arm ABA with magnichanger assembly and NuVar CMO w...

Page 37: ...1 2 Take out the Cross bottom base and put it on floor as shown in Fig 2 3 Open the Box containing Cross Base Top as shown in Fig 3 4 Take out the Cross Base Top and put iron floor as shown in Fig 4...

Page 38: ...ollow the Instruction below a Ensure that the swivel arm lock knob D is loosened b Mount the Arm Assembly into Shaft F c Align three holes E with tapped hole on Shaft F d Use Allen Wrench 4mm and tigh...

Page 39: ...Rotoplate M Re tighten the M4 grub screw e Loosen the M4 grub screw by 2mm allen key on Rotoplate and Fix Ergo Head 0 210 tiltable N and retighten the M4 grub screw f Fix both eyepieces O on ergo head...

Page 40: ...REPLACING THE ILLUMINATION SOURCE a Remove the swivel arm covers by unscrewing the screws in top and bottom as shown in Fig 12 b Remove the connections on the power supply and replace the illuminatio...

Page 41: ...on both sides and insert on the 2 pin inlet F located on Auto Balancing Arm ABA and insert the other end of wire on to point as marked on Auto Balancing Arm ABA for powering operating clutch release a...

Page 42: ...Magna MAGNA 14 3 WIRING CODING DIAGRAM 6129000 795 Issue 1 7 Printed on May 2020 39...

Page 43: ...Intensity Control knob D is located at the front of the Auto Balancing Arm ARM The brightness of the field of view can be adjusted as desired using the intensity control knob as shown in Fig 15 a 3 AU...

Page 44: ...desired height by turning it clock wise as shown in Fig 17 d Auto Balancing Arm ABA Carrier Locking Knob This knob shown as J locks the rotation of Auto Balancing Arm ABA at the desired position by tu...

Page 45: ...sition by using clutch motions shown as A and A 1 to get the proper field of vision as shown in Fig 19 c Desired working distance can be obtained by rotating the ring shown as B on the variable object...

Page 46: ...n as B to achieve fine focus as shown in Fig 19 c Use the Clutch Buttons shown as A on Left handle and A 1 on Right handle to Centre the area of interest in the field of view as shown in Fig 19 Main M...

Page 47: ...ER 6134131 CCD ATTACHMENT 6134110 MONITOR ARM 6129000 877 STAND ASSEMBLY 6129000 813 ARM ASSEMBLY FLOOR MOUNT 6129000 850 MICROSCOPE WITH ABA ARM ASSEMBLY 6129000 851 CEILING MOUNT 6129001 801 ARM ASS...

Page 48: ...d 20 of light goes to camera accessories 3 Double Iris attachment An adjustable diaphragm attachment installed between Magnichanger and observation head or DBSi It reduces incoming light and increases...

Page 49: ...causes LED light blinking as an indicator of high LED temperature Allow the LED to cool down before switching it on again If any optional accessories are added to the microscope suspension arm tension...

Page 50: ...tch 2 Disconnect the power cable 3 Remove the video cable from the video modules e g video monitor USB monitor and the camera control unit 4 Release the brakes 5 Be careful when passing through doorwa...

Page 51: ...to ensure optimum performance and safe working order of the instrument it s safe functioning must be checked periodically as per table below We recommend having this check performance by our service...

Page 52: ...o not clean products and optical components in a cleaning disinfecting devices or ultra sound bath 11 LABOMED Max Lite coating are fungal resistant If you clean as described above the coatings will no...

Page 53: ...in cloth Moist it to feel wet Disinfect clean the surface gently Note 1 Use mask and Gloves while performing cleaning and disinfection 2 While cleaning muslin cloth should not be dripped wet to preven...

Page 54: ...n Control 5 Silicon Cover P N 6122015 210 Knob for IPD inter pupillary distance 6 Silicon Cover P N 6122015 210 Knob for Clutch Handle right side 7 Silicon Cover P N 6129000 232 Knob for Zoom 8 Silico...

Page 55: ...ansportation and Storage Temperature Rel Humidity without condensation Air Pressure Temperature Rel Humidity without condensation Air Pressure 700hPa 1 060hPa 700hPa 1 060hPa 30 90 30 90 10 C 40 C 10...

Page 56: ...igured with Rotoplate DBSi Double Beam Splitter Inclined Double Iris Diaphragm and DSLR Adapter 50 75mm WF 10x 18mm lockable eyepieces one with resolution mark to assist in diopter adjustment 5mm with...

Page 57: ...illumination Inoperative surgical field illumination Insufficient illumination Continued Up and down motion of the suspension system is stiff Insert the light guide as far as it will go Failure of ele...

Page 58: ...Cause Remedy 6129000 795 Issue 1 7 Printed on May 2020 55 Stand is unstable The brakes on the wheels are not in use Engage the brakes No image is visible in the field of view Magnichanger is not index...

Page 59: ...specified below The customer or user of the Magna should ensure that it is used in such an environment RF Emissions CISPR 11 Harmonics IEC 61000 3 2 Flicker IEC 61000 3 3 Complies Class A Group 1 The...

Page 60: ...ne to Ground 2 Kv Outdoor lines only VOLTAGE DIPS DROPOUTS AND INTERRUPTIONS IEC 61000 4 11 Voltage Dips 16A Power Frequency 50 60Hz Magnetic Field IEC 61000 4 8 30A m 30A m 6129000 795 Issue 1 7 Prin...

Page 61: ...s objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcas...

Page 62: ...ed at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximu...

Page 63: ...eight Magna with Wall Mount a Wall Bracket 12Kg b Shaft 07Kg c Magna Arm Long Short 18Kg 14 5Kg d Magna Carrier 11Kg Magna with Ceiling Mount a Ceiling Mount 30Kg b Magna Arm Long 18Kg c Magna Carrier...

Page 64: ...ion intensity is Lux Lx Light Emitting Diode Electronic semiconductor device that emits light when an electrical current passes through it The optical tubes through which the enlarged image produced b...

Page 65: ...nal sale and must be accompanied by a copy of the purchaser s invoice This warranty is in lieu of all other warranties implied or expressed All implied warranties of merchantability or fitness for a p...

Page 66: ...delivery the outside of the packing case shows evidence of rough handling or damage the transportation company s agent should be requested to make a Received in Bad Order notation on the delivery rece...

Page 67: ...hone 510 445 1257 Fax 510 991 9862 Email sales laboamerica com www laboamerica com EU REP A16372 LABOMED ISO 13485 Labomed Europe Essebaan 50 NL 2908 LK Capelle a d IJssel The Netherlands Tel 31 0 10...

Reviews: