11. Monitor
210
If the system memory backup battery is installed, the error list contents will not be cleared even if the
power is turned OFF.
When clearing the error list contents, click the alarm list clear key. A warning in Fig. 11.23 will be
displayed. Clicking Yes will clear the error list contents.
Fig. 11.23 Confirmation
* When trouble occurs, you may be requested to send the error list saved in a file to resolve the problem at
an early stage. The error list file cannot be opened by this PC interface software.
(8) Maintenance information screen
The total number of times the actuator has moved, and total distance travelled by the actuator, are
displayed.
Also, the pairing I.D. of the battery-less absolute encoder can be cleared in this window.
Refer to [How to Clear Paring ID] in this section.
This screen is displayed on the X-SEL-R/S, RX/SX, RXD/SXD, RA/SA, RAX/SAX, RAXD/SAXD controller,
TTA and MSEL controller.
Fig. 11.24 Maintenance Information
Total movement count
: Indicates the accumulated total of times the actuator has moved
Threshold of total movement count
: Indicates the thresholds for the total number of movements
Total mileage [km]
: Indicates the accumulated total of distance travelled by the
actuator
Threshold of total mileage [km]
: Indicates the thresholds for the total distance travelled
Transfer the data of entered new
values to the controller.
Save the maintenance
information data to a file
(CSV format).
Print the maintenance
information data.
Initialize all maintenance information
data. (This button is displayed only
when there is a maintenance
information data error.)
A new value can be entered by the following methods:
• Double-click the cell.
• Press the “Ctrl” and “Space” keys together.
• Press a number key.
Only the alert function threshold can be changed.
Summary of Contents for IA-101-TT-USB
Page 2: ......
Page 4: ......
Page 8: ......
Page 50: ...1 Before You Begin 42 1 4 Connection to Controller Fig 1 48 X SEL K J Type Controller ...
Page 52: ...1 Before You Begin 44 Figure shows example of TT Fig 1 50 Table Top Actuator TT TTA ...
Page 53: ...1 Before You Begin 45 Fig 1 51 X SEL KX JX Type Controller ...
Page 62: ...1 Before You Begin 54 Fig 1 60 ASEL Type Controller USB Cable ...
Page 63: ...1 Before You Begin 55 Fig 1 61 PSEL Type Controller USB Cable ...
Page 189: ...9 Symbol Edit Window 181 ...
Page 251: ...13 How to Reset an Absolute Encoder 243 Fig 13 38 Arm Length 120 Reference Position ...
Page 386: ...16 Appendix 378 ...
Page 391: ......