Table 11-5. DC Characteristics
(when V
CC
= 6.0V ±0.25V, V
PP
= 12.5V ±0.3V, V
SS
= 0V, Ta = 25˚C ±5˚C)
Measurement
Item
Symbol
Min
Typ
Max
Unit conditions
Input High voltage
EO
7
– EO
0
, V
IH
2.4
—
V
CC
+ 0.3 V
EA
14
– EA
0
,
OE, CE
Input Low voltage
EO
7
– EO
0
, V
IL
–0.3
—
0.8
V
EA
14
– EA
0
,
OE, CE
Output High voltage
EO
7
– EO
0
V
OH
2.4
—
—
V
I
OH
= –200µA
Output Low voltage
EO
7
– EO
0
V
OL
—
—
0.45
V
I
OL
= 1.6mA
Input leakage
EO
7
– EO
0
,
|I
LI
|
—
—
2
µA
V
in
= 5.25V/
current
EA
14
– EA
0
,
0.5V
OE, CE
V
CC
current
I
CC
—
—
40
mA
V
PP
current
I
PP
—
—
40
mA
Table 11-6. AC Characteristics
(when V
CC
= 6.0V ±0.25V, V
PP
= 12.5V ±0.3V, Ta = 25˚C ±5˚C)
Measurement
Item
Symbol
Min
Typ
Max
Unit
conditions
Address setup time
t
AS
2
—
—
µs
See figure 11-6*
OE setup time
t
OES
2
—
—
µs
Data setup time
t
DS
2
—
—
µs
Address hold time
t
AH
0
—
—
µs
Data hold time
t
DH
2
—
—
µs
Data output disable time
t
DF
—
—
130
ns
Vpp setup time
t
VPS
2
—
—
µs
Program pulse width
t
PW
0.95
1.0
1.05
ms
Note: * Input pulse level: 0.8V to 2.2V
Input rise/fall time
≤
20ns
Timing reference levels: input—1.0V, 2.0V; output—0.8V, 2.0V