176
Communications Command Examples
Example of saving and loading the measurement conditions
(panel saving and panel loading)
This is an example of saving multiple measurement conditions at once.
Description
Sent to the BT5525 from the
controller
Example of the BT5525 response
(1) Set the test voltage to 500V.
:VOLTage 500
–
(2)
Set the comparator upper/
lower limit values.
:COMParator:LIMit OFF,20E6
–
(3) Saving to panel 1
*SAV 1
–
(4) Set the test voltage to 100V.
:VOLTage 100
–
(5)
Set the comparator upper/
lower limit values.
:COMParator:LIMit
30E6,25E6
–
(6) Saving to panel 2
*SAV 2
–
(7) Loading panel 1
*RCL 1
–
(8) Query the test voltage and
comparator upper/lower limit
values.
:VOLTage?;
:COMParator:LIMit?
500; OFF,20.00E+06
(9) Loading panel 2
*RCL 2
–
(10) Query the test voltage and
comparator upper/lower limit
values.
:VOLTage?;
:COMParator:LIMit?
100;30.00E+06,25.00E+06
•
Multiple measurement conditions can be saved in the instrument and loaded. The areas of the
instrument for storing the measurement conditions are called panels and up to 15 panels (panel 1
to panel 15) can be used for storage.
•
For the save items, see “11.9 Default Setting” (p. 214).
•
In this example, the test voltage of 500 V, the comparator upper limit OFF setting, and the lower
limit of 20 M
Ω
are saved to panel 1. The test voltage of 100 V, the comparator upper limit of
30 M
Ω
, and the lower limit of 25 M
Ω
are saved to panel 2. The two panels are loaded in order
and the settings are checked.
(1) to (3) Set the measurement conditions to be saved to panel 1 and save them to panel 1.
(4) to (6) Set the measurement conditions to be saved to panel 2 and save them to panel 2.
(7) to (8) Load the measurement conditions for panel 1 and check the conditions.
(9) to (10)Load the measurement conditions for panel 2 and check the conditions.
HIOKI BT5525A961-00
Summary of Contents for BT5525
Page 2: ...HIOKI BT5525A961 00 ...
Page 6: ...Contents 6 HIOKI BT5525A961 00 ...
Page 48: ...48 Notifying the Judgment Result and Test Completion with a Beep HIOKI BT5525A961 00 ...
Page 76: ...76 Initializing the Instrument Reset HIOKI BT5525A961 00 ...
Page 82: ...82 Deleting Panel Data HIOKI BT5525A961 00 ...
Page 200: ...200 License Information HIOKI BT5525A961 00 ...
Page 215: ...www hioki com HIOKI BT5525A961 00 ...