9.1 Overview of the Real-Time Saving Function
236
• To use the Real-Time Saving function, at least 3 MB of free space must be
available on the storage media.
• Measurement using different sampling rates is not available with the Real-
Time Saving function.
• The Model 8958 16-Ch Scanner Unit cannot be used.
• Only data for those channels selected for use ([Use Ch] setting enabled on the
Status screen) is measured and saved. However, when a channel is selected
for use, its data is saved even if display of that channel’s waveform is disabled
(off).
• The whole waveform data is recorded in instrument memory. Depending on
the setting of the whole waveform’s timebase (when fast), even if there is suffi-
cient available space on the save destination, only the recording length (dura-
tion) required for the whole waveform is stored. When automatic timebase
setting of the whole waveform is selected (default setting), the timebase of the
whole waveform is set according to the recording length (time).