7.4 Composite Waveforms (X-Y Waveforms)
190
Method 2
View the normal waveform display together with the partial composite
waveform
Set the Display Type on the Sheet Settings screen to
[Wave & X-Y]
, and set the
Composite Area to
[A-B]
. Also make the required settings for the X-Y composite
such as composite channel selections.
Specify the waveform range for the composite on the waveform graph of the
Waveform screen using the
[Vertical]
or
[Trace]
mode of the A/B cursors.
When F1 [XY-Comp] is selected by the [Exec] button in the A/B Cursor dialog,
the composite waveform of the specified range is displayed on the composite
waveform graph.
3
Moves Cursor A
1
2
The composite waveform for the specified
range is displayed.
Markers indicate where the X-Y composite is executed. After the composite is
displayed, you can move the A/B cursors to verify the composite range.
Select the Composite Area
Moves Cursor B
Composite Area Marker
Press the TYPE key
to open the A/B
Cursor dialog.
Move the cursor to the [Exec] button,
and select F1 [XY-Comp].