![Hioki 3155-01 Instruction Manual Download Page 43](http://html1.mh-extra.com/html/hioki/3155-01/3155-01_instruction-manual_2137164043.webp)
23
────────────────────────────────────────────────────
3.2 9196 APPLY UNIT
────────────────────────────────────────────────────
3.2.4 9196 APPLY UNIT Specifications
Output function
Alternating current (AC V)
Output indication
Red monitor lamp
Power indication
Clear monitor lamp
Type toggle
Toggle switch (B/BF, CF)
Polarity toggle
Toggle switch (NORMAL /REVERSE)
Output configuration
Voltage application probe (9190) connector receptacle
Additional functions
Output control function (power cutoff)
Output only when the voltage application button to the 9190 is being pressed.
Dimensions
125W
×
75H
×
230D mm(4.92"W
×
2.95"H
×
9.06"D) (excluding projections)
Mass
Approx. 2.5 kg(88.2 oz.) (excluding accessories)
Accessories
Grounded three-core power cord
Instruction Manual
9190 VOLTAGE APPLY PROBE
Fuse
250 V T0.25 AL 20 mm
×
5 mm dia.
Rated power voltage
100 to 240 VAC
(Voltage fluctuations of 10% from the rated supply voltage are taken into account.)
Rated power frequency 45 to 400 Hz
Maximum rated power
25 VA
Insulation resistance
500 VDC, 100 M
Ω
min. between power supply and frame
Dielectric strength
2.3 kVAC sin (50/60 Hz), 1 minute between power supply and frame
Output breaking
current
6 mAAC typical
Output voltage
110% voltage of the input supply voltage (VAC)
Accuracy
±
(1.0% rdg.+1 V)
B/BF range: In a load current of 5 mA or less
CF range: In a load current of 50
μ
A or less
Operating temperature
and humidity range
5 to 40
℃
(40 to 104
。
F), 35 to 95% rh (no condensation)
Storage temperature
and humidity range
-10 to 50
℃
(14 to 122
。
F), 35 to 95% rh (no condensation)
Accuracy assurance
23
±
5
℃
(73
±
41
。
F), 35 to 80% rh (no condensation)
Operating place
Indoors, max.
2000 m(6562 feet) height
Standards applying
EMC EN55011:1991
EN50082-1:1992
EN61000-3-2:1995
EN61000-3-3:1995
Safety EN61010-1:1993+A.2:1995 Pollution Degree 2,
Overvoltage Category
(anticipated transient overvoltage 2500 V)
General specifications
Electric characteristics
Environmental conditions
Summary of Contents for 3155-01
Page 1: ...LEAK CURRENT HiTESTER INSTRUCTION MANUAL 3155 01...
Page 2: ......
Page 12: ......
Page 27: ...7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 2 Names and Functions of Parts...
Page 45: ...25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 4 Preparations for Measurement...
Page 243: ...223 7 7 System Screen Universal Example of a data unit printout Example of a details printout...
Page 314: ...294...
Page 322: ...302 9 3 Accuracy Tables...
Page 334: ...314 10 6 External Dimensions 292 2 110 2 212 2 115 8 2 10 6 External Dimensions...
Page 335: ...315 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 APP Appendices...
Page 362: ...INDEX 6 Index...
Page 363: ......
Page 364: ......
Page 365: ......