![Hioki 3155-01 Instruction Manual Download Page 315](http://html1.mh-extra.com/html/hioki/3155-01/3155-01_instruction-manual_2137164315.webp)
295
────────────────────────────────────────────────────
9.1 General Specifications
────────────────────────────────────────────────────
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Measurement functions
Leakage current measurement
Low resistance measurement
Monitor functions
Line voltage
Current consumption of the equipment to be measured
Power line ground
Display
5-inch LCD, 320
×
240 dots (back light)
Operation keys
6
×
6 matrix touch panel
Recording
Thermal serial printer (paper width: 58 mm)
Clock functions
Auto-calendar, automatic leap year calculation, 24-hour system
Data Storage
Space to store data for 100 unit
Data stored: number, model name, maximum value and condition of the
equipment to be measured
Operating temperature and
humidity range
5 to 40
℃
(41 to 104
。
F), 35 to 80% rh (no condensation)
Storage temperature and
humidity range
-10 to 50
℃
(14 to 122
。
F), 35 to 95% rh (no condensation)
Temperature and humidity
range to guarantee
specification
23
±
5
℃
(73
±
41
。
F), 35 to 80% rh (no condensation)
Operating place
Indoors, max. 2000 m(6562 feet) height
Backup battery lifetime
Average of 8 years (at 25
℃
(17
。
F) reference value), for clock, settings, etc.
Backup battery lifetime
Average of 8 years (at 25
℃
(17
。
F) reference value), for clock, settings, etc.
Power supply
Rated power voltage
3155: 120/200/240 VAC (Specify at order.)
3155-01: 110 to 120/200/240 VAC (switchable)
(Voltage fluctuations of 10% from the rated supply voltage are taken into
account.)
Rated power frequency 50/60 Hz
Maximum rated power
30 VA
Insulation resistance
500 VDC, 100 M
Ω
min. between power supply and frame
Dielectric strength
2.3 kVAC (10 mA), 1 minute between power supply and frame
Maximum rated power of the
auxiliary outlet
1500 VA max.
Outlet over-current protection Over-current cutoff
Chapter 9
Specifications
9.1 General Specifications
Summary of Contents for 3155-01
Page 1: ...LEAK CURRENT HiTESTER INSTRUCTION MANUAL 3155 01...
Page 2: ......
Page 12: ......
Page 27: ...7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 2 Names and Functions of Parts...
Page 45: ...25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 4 Preparations for Measurement...
Page 243: ...223 7 7 System Screen Universal Example of a data unit printout Example of a details printout...
Page 314: ...294...
Page 322: ...302 9 3 Accuracy Tables...
Page 334: ...314 10 6 External Dimensions 292 2 110 2 212 2 115 8 2 10 6 External Dimensions...
Page 335: ...315 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 APP Appendices...
Page 362: ...INDEX 6 Index...
Page 363: ......
Page 364: ......
Page 365: ......