Chapter 4 Parameters
4-37
Group 13: PG function Parameters for Extension Card
Parameter Explanation
Settings
Factory
Setting
Customer
13.00 PG
Input
0: Disabled
0
1: Single phase
2: Forward/Counterclockwise rotation
3: Reverse/Clockwise rotation
13.01
PG Pulse Range
1 to 20000
600
13.02
Motor Pole Number
(Motor 0)
2 to 10
4
13.03
Proportional Gain
(P)
0.0 to 10.0
1.0
13.04
Integral Gain (I)
0.00 to 100.00 sec
1.00
13.05
Speed Control
Output Frequency
Limit
0.00 to 100.00Hz
10.00
13.06
Speed Feedback
Display Filter
0 to 9999 (*2ms)
500
13.07
Detection Time for
Feedback Signal
Fault
0.0: disabled
0.1 to 10.0 sec
1.0
13.08
Treatment of the
Feedback Signal
Fault
0: Warn and RAMP to stop
1
1: Warn and COAST to stop
2: Warn and keep operation
13.09
Speed Feedback
Filter
0 to 9999 (*2ms)
16
13.10
Source of the High-
speed Counter
0: PG card
Read
Only
1: PLC (NOT for VFD*E*C models)