E-12
Definition of Index:
Index
Sub
Definition
Factory
Setting
R/W Size Unit
NOTE
0x1000 0 Abort
connection
option code
0x00010192
RO U32
0x1001 0 Fault
register
0 RO U8
0x1005 0
COB-ID SYNC
message 0x80
RW U32
0x1006 0
Communication cycle
period 0
RW U32 us
500us~15000us
0x1008 0
Manufacturer device
name 0
RO U32
0x1009 0
Manufacturer
hardware version
0
RO U32
0x100A 0
Manufacturer software
version 0
RO U32
0x100C
0 Guarding time
0 RW U16
ms 0x80 + node 1
0x100D 0 Guarding
factor
0 RW U8
0x1014 0 COB-ID
emergency
0x0000080
+Node-ID
RO U32
0x1015
0 Inhibit time EMCY
0
RW U16 100us
It is set to be
multiple of 10.
0x1016
0 Number
0x1 RO U8
1
Consumer heartbeat
time
0x0 RW U32 1ms
Heartbeat time can
be used when
Guarding time is
invalid.
0x1017 0
Producer heartbeat
time
0x0 RW U16 1ms
Heartbeat time can
be used when
Guarding time is
invalid.
0x1018
0 Number
0x3 RO U8
1 Vender
ID
0x000001DD RO U32
2 Product
code
0x00002600
+model
RO U32
3 Revision
0x00010000 RO U32
0x1200
0
Server SDO
Parameter 2
RO U8
1
COB-ID Client ->
Server
0x
Node-ID
RO U32
2
COB-ID Client <-
Server
0x
Node-ID
RO U32
0x1400
0 Number
2 RO U8
1 COB-ID used by PDO
0x00000200
+Node-ID
RW U32
2 Transmission
Type
5 RW U8
00:Acyclic &
Synchronous
01~240:Cyclic &
Synchronous
255: Asynchronous
0x1401 0 Number
2 RO U8