Chapter 4 Parameters
4-162
Group 11: Multi-function Input/Output Parameters for Extension Card
11.00
Multi-function Output Terminal MO2/RA2
11.01
Multi-function Output Terminal MO3/RA3
11.02
Multi-function Output Terminal MO4/RA4
11.03
Multi-function Output Terminal MO5/RA5
11.04
Multi-function Output Terminal MO6/RA6
11.05
Multi-function Output Terminal MO7/RA7
Settings
0 to 24
Factory Setting: 0
Please make sure that the extension card is installed on the AC motor drive correctly, the
extension card will be detected automatically thus the Pr. Group 11
will be displayed,
and you
can set the parameters.
If there is no extension card installation, the parameters only can
display and set Pr. Group 0 ~ Group 10. See Appendix B for details.
Please refer to Pr.03.01 function table for Multi-function output terminal function settings.
Please set the parameters according to the terminal name on the extension card.
11.06
Multi-function Input Terminal (MI7)
11.07
Multi-function Input Terminal (MI8)
11.08
Multi-function Input Terminal (MI9)
11.09
Multi-function Input Terminal (MI10)
11.10
Multi-function Input Terminal (MI11)
11.11
Multi-function Input Terminal (MI12)
Settings
0 to 28
Factory Setting: 0
Refer to the table below Pr.04.08 for setting the multifunction input terminals.
Set the corresponding parameter according to the terminal labeled on the extension card.