B-25
Input / Output
EME-A22A
Terminal Description
AI1
AI2
Input voltage range
:
0 ~ 10VDC =0 ~ Max. output frequency(Pr.01.00)
Input impedance
:
100K
Ω
Resolution
:
12 bits
Input current range
:
DC 0 ~ 20mA=0 ~ Max. output frequency (Pr.01.00)
Input impedance
:
250
Ω
Resolution
:
12 bits
AO1
AO2
Input voltage range
:
DC 0 ~ 10V
Input impedance
:
1K ~ 2M
Ω
Resolution
:
12 bits
Input current range
:
DC 0 ~ 20mA
Input impedance
:
0 ~ 500
Ω
Resolution
:
12 bits
ACM
Analog control signal common terminal
Warning:
To connect the inductive load (relay, electromagnetic contactors, motor ... etc.
)
, please
install RC network or Varistor beside the coil.
Please install fuse (the spec can
’
t greater than contact limits) in the loops for safety
concern.
Please use isolated cable to prevent the interface as far as possible.
Please have soldering or terminal for cable.
Based on the safety considerations, please keep more than 15cm with other control, motor
and power cables and wiring independently; please keep the vertical wiring if it is
necessary for cable staggering.
All operations can NOT exceed the limitation of spec.
Dimensions: Unit: mm [inch]
49.5 [1.95]
32.5 [1.28]
52.0 [2.05]
11.6 [0.46]
15.4 [0.60]
45.0 [
1.77]