background image

Product

Product

Manual

Manual

Power

Power

inverter/ups

inverter/ups

Shenzhen

Shenzhen

ORO

ORO

Power

Power

Equipment

Equipment

CO.,LTD

CO.,LTD

Address

Address

:

:

Dunfa

Dunfa

industrial

industrial

park,

park,

Building

Building

6

6

layer,

layer,

Hangcheng

Hangcheng

Road

Road

,Xixiang

,Xixiang

Gushu,Baoan

Gushu,Baoan

District,Shenzhen,Guangdong,China

District,Shenzhen,Guangdong,China

Before designing and during the production, the safety of operators and products all have been

considered. Please following this users instructions strictly to operate or install the machine in

case of personal injury or accident occur.

(1)The installation of the inverter should be done by professionals or under the assistance of the local

dealer.
(2)Verify whether the input DC voltage range meets the requirements ±15% and the correctness of
voltage polarity.
(3)Confirm the grade of load device voltage ,power should not be more than rated output power of

the inverter

(4)Do not flow any liquid inside the inverter, or with a damp cloth to wipe the machine casing. Can

not be directly Contact the inverter input and output terminals when the machine is running,

especially with wet hands, otherwise electric shock injury will occur.

(5)If you need to change the working environment under the normal working state, do not change its

connection, your operated should be assistance and confirmation by the professionals or supplier.

(6)The operating environment of inverter should be well-ventilated, temperature range -20-45

degrees, keep away from the ignition sources spot and direct sunlight, Can not run in the

condensation, dust environment. During the operating, the heat is normal phenomenon, should

maintain the ventilation, clean installation environment, in particular, can not block the ventilation

holes.

(7)Minors can not use this product.

(8)Confirm weather the inverter can be connected with the earth wire,Live line and Zero line can not

Summary of Contents for DC12V-AC220V

Page 1: ...e of load device voltage power should not be more than rated output power of the inverter 4 Do not flow any liquid inside the inverter or with a damp cloth to wipe the machine casing Can not be directly Contact the inverter input and output terminals when the machine is running especially with wet hands otherwise electric shock injury will occur 5 If you need to change the working environment unde...

Page 2: ...ind of power inverter upgraded and promote completely according to the adavantages and disadvantages of old ones use latest power efficiency technology with high convert efficiency stable performance low no load consumption strong overload capacity strong anti jamming capability supply pure sine wave AC power for commercial industry communication civilian army It is suitable for DC12V 24V 48V 72V ...

Page 3: ... 2 Intelligent charge 1 Charge different kinds of batteries refer to the parameter of product page five of this manual 2 Three charge stages Stage 1 the charger will run at full current in CC mode until the charger reaches the boost voltage Activate battery promote power constant current charging Stage2 the charger will keep the boost voltage in Boost CV mode give battery enough time to absorb ene...

Page 4: ... lead acid batteries open lead acid batteries gel batteries seven kinds of batteries Note lithium batteries need to setting as customers use specifications before the delivery 6 Intelligent temperature control fan more energy and longer life 7 This series of products with a carrying capacity superior anti load capacity it can with load of water pumps air conditioners refrigerators etc rated power ...

Page 5: ...1 AC voltage AC110V 100V 120V 230V 240V 2 Charge from Utility Grid UPS function 3 Frequency 50HZ 60HZ automatic selection DC24V AC220V 300W 600W 800W 1KW 1 5KW 2KW 3KW 4KW 5KW 6KW DC48V AC220V 300W 600W 800W 1KW 1 5KW 2KW 3KW 4KW 5KW 6KW 7KW 8KW 10KW 12KW DC72V AC220V 1 5KW 2KW 3KW 4KW 5KW 6KW 7KW 8KW 10KW 12KW postscript DC36V and any other would be customized 5 Parameters Solar inverter paramete...

Page 6: ...han this turn to utility electricity to supply 11Vdc 0 3Vdc 12V 22Vdc 0 6Vdc 24V 44Vdc 1 2Vdc 48V 66Vdc 1 8Vdc 72V DC priority type after turning to utility electricity to supply the battery low voltage recovery point when the battery s voltage is higher than this turn to battery to supply electricity 13 5Vdc 0 3Vdc 12V 27 0Vdc 0 6Vdc 24V 54 0Vdc 1 2Vdc 48V 81 0Vdc 1 8Vdc 72V AC Input Specificatio...

Page 7: ...e Continuous operation Normal Boot no load Depletion Rated Power 2 5 No load Depletion of energy saving mode 6W Safety Certification CE EN62040 1 EMC EN62040 2 C2 Communication Interface RS232 Customizable Cooling Temperature controlled variable speed fan cooling Ventilation condition Noise dB 1 meter 60dB Ambient temperature ºC 10 45 Storage Temperature ºC 20 55 Using Environment Humidity 0 95 re...

Page 8: ...35 A 20A 65A 35A 75A 45A 65A 35A 70A 40A 75A 50A DC Voltage 48 V 72V 48V 72V 48V 72V 72V 72V 72V Charge current 9A 6A 15A 10A 30A 15A 20A 25A 30 MCB 10A 20A 30A 30A 30A 30A Model Specification 8KW 10KW 12KW Switch Gears Description of corresponding batter s type Open circuit Floating Charging Voltage Voltage 12V 24V 48V 12V 24V 48V 0 Cancell Charge Not charging cancell utility grid charging functi...

Page 9: ...ode until the charger reaches the boost voltage Boost CV Stage the charger will keep the boost voltage in Boost CV mode Then drop the voltage down to the float voltage The timer has a minimum time of 1 hour and a maximum time of 12 hours Float Stage In float mode the voltage will stay at the float voltage If the AC is reconnected or the battery voltage drops below 12Vdc 24Vdc the charger will rese...

Page 10: ...th RED indicator on stand for inverter Alarm Battery type 10 dial up switch set battery type refer to part 6 Two dial up 50 60 Set frequency by yourself 50HZ or 60HZ AC DC Choose way of supplying Give priority to AC or DC Next Page Press the button can turn page and open a backlight 2 LCD display 1 Inverter status P Grid status No outload display Broken status Broken description Table 1 Bat Vol 01...

Page 11: ...icator on stand for Fast Charging Mode INVERTER ON Sixth GREEN LED indicator on stand for Inverter Mode UTILITY GRID Seventh GREEN LED indicator on stand for AC Mode CHARGER Eighth GREEN LED indicator on stand for Battery Charger Mode INVERTER Ninth GREEN LED indicator on stand for Inverter Mode ALARM Tenth RED LED indicator on stand for Alarm 4 Alarm and protection Broken alarm Broken type displa...

Page 12: ... 0 5s Protection Over Temperature Protection Cooling fin temp 105ºC start to protect after 30 seconds Shutdown Output Back Feed Protection Yes Automatic Restart The resumption of work after fault Mode of operation restart the inverter 9 The Connection Instruction of Solar wind power inverter 1 Horizontal type 300W 6KW connection instruction DC DC Remote port DC INPUT 12V24V48V Charger input protec...

Page 13: ...attery positive electrode red blinding post Remote port signal indicate Control interface and back ground RS232 customize E ground line Charger input protect Utility grid input charging over current protector Inverter output protect Inverter power output over current protector AC input port output port Attention Level of AC voltage AC INPUT L Live line N zero line E ground line AC OUTPUT L Live li...

Page 14: ...electrode connect battery negative electrode red blinding post Remote port DB 9 6 DB 9 7 DB 9 8 DB 9 9 customize RS232 back ground RS232 DB 9 2 TX DB 9 3 RX DB 9 5 GND AC OUTPUT two multifunctional sockets output Max current of each one is 8A AC OUTPUT two terminal ac input L1 L2 power line N1 N2 zero line E ground line AC INPUT SW air switch of ac input AC OUTPUT SW air switch of ac output AC INP...

Page 15: ...perature control fan Give priority to DC Control Item Start Stop speed Temperature of radiator T 60 T 65 OFF 65 T 85 T 60 or T 85 50 T 85 T 80 100 Charge current I 15 I 20 OFF 20 I 50 Max I 15 or I 50 Max 50 I 50 Max I 40 Max 100 Load rate inverter Load 30 Load 30 OFF 30 Load 50 Load 20 or Load 50 50 Load 50 Load 40 100 Temperature of system 55 T 42 50 T 55 100 ...

Page 16: ...Battery Low volt beep 0 5s every 5s Battery Over volt beep 0 5s every 1s Overload on invert mode Refer to Audible alarm Over Temp on invert mode Beep 0 5s every 1s Over Temp on P grid mode beep 0 5s every 1s Over charge beep 0 5s every 1s Broken Mode Fan broken beep continuous Battery Over volt beep continuous Over load on Inverter mode beep continuous Over Temp beep continuous Over charge beep co...

Page 17: ...k Float charge Standby Inverter mode Turn on Power saver Alarm Mode Battery Low vol beep 0 5s every 5s Battery over vol beep 0 5s every 1s Overload on invert mode Refer to Audible alarm OverTemp on invert mode Beep 0 5s every 1s OverTemp on P Grid beep 0 5s every 1s Over charge beep 0 5s every 1s Broken Mode Fan broken beep continuous Battery over vol beep continuous Overload on Inverter mode beep...

Page 18: ...Appendix3 Product Warranty Cards Warranty Card Products name Item number Model Purchase date Warranty Buyer Contacts Tel Distributor Maintenance Record date ...

Reviews: