B.8.2 Profibus Communication Module (CME-PD01)
B.8.2.1 Panel Appearance
NET SP
ADDL
ADDH
Address Swithes
NET LED
SP LED
Profibus-DP
Interface (DB9)
RJ485 (RJ-45)
1: Reserved
2. EV
3. GND
4. SG-
5. SG+
6. Reserved
7. Reserved
8. Reserved
1. SP LED: Indicating the connection status between VFD-E and CME-PD01.
2. NET LED: Indicating the connection status between CME-PD01 and PROFIBUS-DP.
3. Address Switches: Setting the address of CME-PD01 on PROFIBUS- DP network.
4. RS-485 Interface (RJ45): Connecting to VFD-E, and supply power to CME-PD01.
5. PROFIBUS-DP Interface (DB9): 9-PIN connector that connects to PROFIBUS-DP
network.
6. Extended Socket: 4-PIN socket that connects to PROFIBUS-DP network.
B.8.2.2 Dimensions
Unit: mm[inch]
3.6 [0.14]
72.0 [2.83]
63.3
[2.49]
34.8 [1.37]
3.5 [0.14]
38.3 [1.51]
5
7.3 [2.2
6]
B.8.2.3 Parameters Settings in VFD-E
VFD-E
Baud Rate 9600
Pr.09.01=1
RTU 8, N, 2
Pr.09.04=3
Freq. Source
Pr.02.00=4
Command Source
Pr.02.01=3