Status Code
559
016-450
[Cause] The SMB host name already exists.
[Remedy] Change the host name.
Refer to "Host Name" (P.332).
016-453
[Cause] Updating of the IPv6 address and host name for the DNS server failed.
[Remedy] Check whether the IP address of the DNS server is set correctly.
016-454
[Cause] Unable to retrieve the IP address from DNS.
[Remedy] Confirm the DNS configuration and IP address retrieve setting.
Refer to "Protocol Settings" (P.328).
016-455
[Cause] Connection to the SNTP server timed out.
[Remedy] Confirm the network cable connection and the IP address of the SNTP server are
correct.
Refer to "Machine Clock/Timers" (P.295).
016-456
[Cause] Received a message from the SNTP server stating that the server is not synchronized
with the standard time source.
[Remedy] Confirm the SNTP server settings.
Refer to "Machine Clock/Timers" (P.295).
016-500
016-501
016-502
[Cause] An error occurred.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. If the same message is displayed again, contact Customer
Support at
dell.com/contactdell
.
016-503
[Cause] Unable to resolve the SMTP server name when sending e-mail.
[Remedy] Check on Dell Printer Configuration Web Tool whether the SMTP server settings are
correct. Also, confirm whether the DNS server settings are correct.
016-504
[Cause] Unable to resolve the POP3 server name when sending e-mail.
[Remedy] Check on Dell Printer Configuration Web Tool whether the POP3 server settings are
correct. Also, confirm whether the DNS server settings are correct.
016-505
[Cause] Unable to log into the POP3 server when sending e-mail.
[Remedy] Check on Dell Printer Configuration Web Tool whether the user name and password
used on the POP3 server are correct.
016-513
[Cause] An error occurred in connecting to the SMTP server. Probable causes are as follows:
1)The SMTP server or network may be overloaded.
2)The source port number for SMTP is incorrect.
[Remedy] For 1), wait for a while, and then execute the operation again.
For 2), confirm whether the source port number for SMTP is correct.
016-514
[Cause] An error occurred during processing of an XPS document.
[Remedy] If an error occurred while printing from a driver which supports XPS, print from the
application using another print driver (PCL, etc.).
If an error occurred while direct printing an XPS document (such as E-mail and Media
Print - Text), print using the print driver (PCL, etc.) from XPS Document Viewer.
Note
•
XPS stands for XML Paper Specification.
Status Code
Cause and Remedy
Summary of Contents for C5765DN
Page 1: ...Dell C5765dn Color Laser Multifunction Printer User s Guide Regulatory Model C5765dn ...
Page 48: ...2 Product Overview 48 ...
Page 132: ...4 Fax 132 4 Select Save 5 Press the Start button ...
Page 144: ...5 Scan 144 ...
Page 176: ...9 Media Print Text and Photos 176 ...
Page 278: ...14 Machine Status 278 ...
Page 424: ...16 Dell Printer Configuration Web Tool Settings 424 ...
Page 650: ...23 Install Operation for Eco copy My Forms 650 ...