ESIE15-08B
|
Part 2. Troubleshooting
4. Component checklist - Water Circuit
Page 70
19/07/16
Daikin Altherma Monobloc CA
4.3. Thermistors
1.
Switch off the Daikin Altherma Monobloc CA via the user interface.
2.
Switch off the Daikin Altherma Monobloc CA with the field supplied circuit breaker.
3.
Locate the thermistor and check if thermal contact with the piping or ambient is ensured.
Technical specification
Description
2 different types of thermistors are used; the resistance vs. temperature charac-
teristic for each type is shown in Table 2-5 on page 90.
The thermistors are used to measure the temper-
ature at multiple locations inside the Daikin
Altherma
Monobloc CA
. The measured tempera-
tures are processed by the A1P board.
Location
Wiring diagram (R1T, R3T, R4T)
Switch box
Unit
Wiring diagram (R1T, R5T)
Control box
Unit
Wiring diagram (R2T)
BUH Kit
Unit
Check procedure