ESIE15-08B
|
Part 3. Repair
2. Unit specific repair procedures Monobloc CA
19/07/16
Page 133
Daikin Altherma Monobloc CA
2.2.13. Replacing the water pump M1P
2.2.13.1 Preliminary actions
1.
Switch off the Daikin Altherma Monobloc CA via the user interface.
2.
Switch off the Daikin Altherma Monobloc CA with the field supplied circuit breaker.
2.2.13.2 Procedure
Removal
1.
Empty, the water circuit, refer to the Installer Reference guide.
2.
Loosen and remove the 2 screws that fix the hydrobox switch box cover plate.
3.
Remove the hydrobox switch box cover plate.
4.
Unplug connector X16A and X25A PCB A1P.
5.
Cut all tie wraps that fix the water pump wiring.
6.
Loosen the 4 screws (1) that fix the water pump M1P(2).
7.
Figure 24 - Removing the water pump M1P
W
ARNING
: R
ISK
OF
F
IRE
•
When reconnecting a connector to the PCB, do not apply force or damage the connector or the connector pins on
the PCB.
1. Screw
2. Water pump M1P
2
1
1