ESIE15-08B
|
Part 3. Repair
2. Unit specific repair procedures Monobloc CA
Page 120
19/07/16
Daikin Altherma Monobloc CA
Figure 13 - Removing the PCB assembly main - 1
4.
Unplug Faston plugs HL402 (3) and HN402 (4) from the PCB2 inverter.
5.
Unplug Faston plugs DCP2 (5) and DCM2 (6) from the PCB2 inverter.
6.
Unplug connectors S411 (7) and S401 (8), from the PCB2 inverter.
7.
Unplug connectors S206 (9), S209 (10), S210 (11), S10 (12), S20 (13), S40 (14), S50 (15), S60 (16), S90 (17), MR30_A (18)
and MR30_B (19) from the PCB assembly main (5).
8.
Unlock the PCB latches (8) (Figure 13) and remove the PCB assembly main (5).
1. Latch
5. PCB assembly main
2. Electrical component box cover
6. Screw
3. Electrical component box
7. Ground wires E1, E2
4. Screw
8. PCB latch
1
8
1
1
2
1
4
5
3
8
6
7
8