1.3. Products
1.3.1. Required products when servicing the Daikin Altherma Monobloc CA
Some Daikin Altherma Monobloc CA parts are sealed and must be sealed again after replacement. Only use the same thread
sealant (1) whenever required.
When replacing R10T it might be necessary to apply some heat sink compound (2).
Figure 3 - Required products
1.4. Tools
1.4.1. Required special tooling when servicing the Daikin Altherma Monobloc CA
Daikin strongly recommends to use special tools to avoid damage to the equipment or to facilitate the replacement of certain spare
parts.
Figure 4 - Required tools
1. Thread sealant (Permabond A131, local supply)
2. Heat sink compound (Part number 999308P)
1. Cooling clamp
3. Pliers wrench (Knipex 87 05 300 or equivalent)
2. Pliers wrench (Knipex 86 03 300 or equivalent)
4. Welding blanket