5 - 6
l M a i n t e n a n c e
C l e a n i n g t h e M i x e r
1
Once the material compartment has been cleaned, remove the deflector.
This will
enable you to clean the mixing chamber and the shut off valve at the bottom of the
chamber. You may need to run the mixing agitator for a short time to fully evacuate the
mixing chamber. If not necessary, skip to step 6.
2
Close the mix chamber access door.
3
Restore power by closing the main disconnect switch.
4
Manually run the mixer for a short time to lower the material level.
Refer to the
Operation section entitled, Menus-Manual Control
to see how to run the mixer manual-
ly.
5
If applicable, open the discharge slide gate at the bottom of the mix chamber.
6
Open the mix chamber access door.
The safety switch will prevent operation of the
mixer with the door open.
✒
Tip
: If using the optional drain chute with safety interlock, open the front access door, remove the
weigh bin, and position the chute to direct material into a bucket or drum rather than the mix chamber.
7
In the “Home” screen, press More/Setup/Maintenance/Manual Control
.
8
Press on the appropriate valve icon to open the selected valve gate.
C A U T I O N : M i x b l a d e h a z a r d
There are two hazards associated with the mix blades. First, the blades are driven
with substantial torque. Never place your hand in the mix chamber unless power is
completely disconnected and appropriate lock out/tag out procedures have been
followed. Second, the mix blades may become razor sharp. Always be careful when
touching or cleaning these blades. Check for sharp edges frequently. Replace
blade if a hazard exists.
TB45-100 Mix Chamber
TB250-500-900 Mix Chamber
(Continued)
Summary of Contents for TrueBlend SB-4
Page 6: ...iv l Table of Contents...
Page 38: ...3 10 l Installation...
Page 134: ...4 96 l Operation...
Page 160: ...6 10 l Troubleshooting...
Page 165: ...Appendix l C 2 Hole Locations for Blow Off Kit...
Page 168: ...D 3 l Appendix...