![YASKAWA CIPR-GA50C series Скачать руководство пользователя страница 671](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765671.webp)
YASKAWA
SIEPC71061753A GA500 Technical Manual
671
Note:
•
You can set this parameter when
C6-02 = B [Carrier Frequency Selection = Leakage Current Detection Reduction Rate PWM]
.
•
When the setting value increases, the current monitor will start up slowly. Examine the relevant sequence for problems.
If errors occur in the values on the current monitor during acceleration/deceleration, increase the setting value.
◆
L2: Power Loss Ride Through
L2 parameters
set the drive operation during momentary power loss and the KEB Ride-Thru function method of
operation.
■
KEB Ride-Thru Function
KEB is an acronym for Kinetic Energy Backup. If the drive detects a power loss or momentary power loss, it will
quickly decelerate the motor. The drive uses regenerative energy from the motor to keep the main circuit
operating. When you return power during motor deceleration, the drive returns operation to the status before the
power loss. The KEB Ride-Thru function is different than other functions for continuous operation. If the drive
detects momentary power loss, the motor will ramp to stop. It will not coast to stop. This function is applicable for
applications in which it is necessary to prevent materials from running out, for example control for film and fiber
lines.
The KEB Ride-Thru function has 4 methods of operation. Parameter
L2-29 [Kinetic Energy Backup Method]
sets
the method.
When you use the KEB Ride-Thru function with one drive, set
L2-29 = 0, 1 [Single Drive KEB Ride-Thru 1,
Single Drive KEB Ride-Thru 2]
.
If deceleration in coordination with more than one drive is necessary, for example textile machinery line systems,
set
L2-29 = 2, 3 [System KEB Ride-Thru 1, System KEB Ride-Thru 2]
.
Table 12.66 KEB Ride-Thru Function Operation Method
L2-29
Kinetic Energy
Backup Method
Operation
Configuration Precautions
0
Single Drive KEB
Ride-Thru 1
The drive uses regenerative energy from the motor to keep the DC bus
voltage at the level set in
L2-11 [KEB DC Bus Voltage Setpoint]
while
it adjusts the rate of deceleration.
The KEB operation continues while the drive adjusts the deceleration
rate with the setting of
C1-09 [Fast Stop Time]
.
•
Set C1-09 correctly to prevent
Uv1 [DC Bus Undervoltage]
and
ov
[Overvoltage]
.
•
If the drive detects
Uv1
during the KEB operation, decrease the
value set in
C1-09
.
•
If the drive detects
ov
during the KEB operation, increase the value
set in
C1-09
.
1
Single Drive KEB
Ride-Thru 2
The drive uses information about the inertia of the connected
machinery to find the deceleration rate necessary to keep the DC bus
voltage at the level set in parameter
L2-11
.
The drive uses system inertia to calculate the deceleration time. You
cannot adjust this value.
•
If the drive detects
Uv1
during the KEB operation, increase the
setting value of
L3-20 [DC Bus Voltage Adjustment Gain]
and
L3-
21 [OVSuppression Accel/Decel P Gain]
.
•
If the drive detects
ov
during the KEB operation, decrease the
setting values of
L3-20
and
L3-21
.
2
System KEB Ride-
Thru 1
The drive does not monitor the DC bus voltage. The drive decelerates
at the KEB deceleration time set in
L2-06
.
Use
L2-06
to set the time necessary to decelerate from the current
frequency reference to 0 Hz. More than one drive can decelerate and
keep a constant speed ratio between drives.
Use the dynamic braking option with System KEB Ride-Thru 1.
3
System KEB Ride-
Thru 2
The drive uses the KEB deceleration time set in
L2-06
to decelerate
and it also monitors the DC bus voltage.
If the voltage level increases, the drive momentarily holds the
frequency to prevent an
ov
before it continues to decelerate.
If you cannot use the dynamic braking option, use System KEB Ride-
Thru 2.
■
KEB Ride Thru Start
When
L2-01 = 3, 4, 5 [Power Loss Ride Through Select = Kinetic Energy Backup: L2-02, Kinetic Energy
Backup: CPU Power, Kinetic Energy Backup: DecelStop]
, the drive starts the KEB operation immediately after it
detects a momentary power loss. When one of these conditions occur, the drive will activate KEB Ride-Thru:
•
KEB Ride-Thru 1 set for the MFDI terminal becomes enabled (terminal is deactivated when
H1-xx = 65
or
terminal is activated when
H1-xx = 66
).
The drive uses the mode selected
L2-29 [Kinetic Energy Backup Method]
to start KEB operation.
•
KEB Ride-Thru 2 set for the MFDI terminal becomes enabled (terminal is deactivated when
H1-xx = 7A
or
terminal is activated when
H1-xx = 7B
).
The drive automatically starts Single KEB Ride-Thru 2 and it ignores the setting of L2-29.
•
The DC bus voltage is less than the level set in
L2-05 [Undervoltage Detection Lvl (Uv1)]
.
The KEB operation will start as specified in
L2-29
.
Note:
If you try to set KEB Ride-Thru 1 and 2 to the MFDI terminals at the same time, it will trigger
oPE03 [Multi-Function Input Setting
Err]
.
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...