Note:
To get the same qualities as a Yaskawa 1000-series drive or previous series drive, set this parameter =
T1-03 [Motor Rated Voltage]
.
◆
T2: PM Motor Auto-Tuning
T2 parameters
set the Auto-Tuning input data for PM motor tuning.
Note:
The drive automatically sets these PM motor parameters:
•
E1-xx [V/f Pattern for Motor 1]
•
E5-xx [V/f Pattern for Motor 1]
■
T2-01: PM Auto-Tuning Selection
No.
(Hex.)
Name
Description
Default
(Range)
T2-01
(0750)
PM Auto-Tuning Selection
Sets the type of Auto-Tuning for PM motors.
0
(Determined by A1-02)
Note:
Yaskawa recommends Rotational (Ld, Lq, R, back-EMF) for specialized motors. Rotational Auto-Tuning rotates the motor to measure
the actual induction voltage constants for more accurate control than Stationary Auto-Tuning.
0 : Manual Entry w/ Motor Data Sheet
1 : Stationary (Ld, Lq, R)
2 : Stationary (R Only)
4 : PM Motor Code Selection
5 : High Frequency Injection
■
T2-02: PM Motor Code Selection
No.
(Hex.)
Name
Description
Default
(Range)
T2-02
(0751)
PM Motor Code Selection
If the drive is operating an SMRD, SMRA, or SSR1 series Yaskawa PM motor, enter the PM
motor code in to align with the rotation speed and motor output.
Determined by A1-02 and
o2-04
(0000 - FFFF)
Enter the motor code to automatically set parameters
T2-03 to T2-14
. When you are operating a specialized motor
or a non-Yaskawa motor, set
T2-02 = FFFF
and enter the data from the motor nameplate or the motor test report.
You can only enter the permitted PM motor codes. Different drive control methods will accept different PM motor
codes.
■
T2-03: PM Motor Type
No.
(Hex.)
Name
Description
Default
(Range)
T2-03
(0752)
PM Motor Type
Sets the type of PM motor the drive will operate.
1
(0, 1)
0 : IPM motor
1 : SPM motor
■
T2-04: PM Motor Rated Power
No.
(Hex.)
Name
Description
Default
(Range)
T2-04
(0730)
PM Motor Rated Power
Uses the units set in
o1-58 [Motor Power Unit Selection]
to set the PM motor rated output power.
Determined by o2-04, C6-
01
(0.00 - 650.00 kW)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...