![YASKAWA CIPR-GA50C series Скачать руководство пользователя страница 349](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765349.webp)
YASKAWA
SIEPC71061753A GA500 Technical Manual
349
◆
C3: Slip Compensation
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
C3-01
(020F)
RUN
Slip Compensation Gain
Sets the gain for the slip compensation function. Usually it is not necessary to change
this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
•
E2-01 [Motor Rated Current (FLA)]
•
E2-02 [Motor Rated Slip]
•
E2-03 [Motor No-Load Current]
Determined by A1-02
(0.0 - 2.5)
C3-02
(0210)
RUN
Slip Compensation
Delay Time
Sets the slip compensation delay time when speed is unstable or when the slip
compensation response is too slow. Usually it is not necessary to change this setting.
Determined by A1-02
(0 - 10000 ms)
C3-03
(0211)
Slip Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor
rated slip.
200%
(0 - 250%)
C3-04
(0212)
Slip Compensation at
Regen
Sets the slip compensation function during regenerative operation.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
0
(0 - 2)
C3-05
(0213)
Output Voltage Limit
Selection
Sets the automatic reduction of motor magnetic flux when the output voltage is
saturated.
0 : Disabled
1 : Enabled
0
(0, 1)
C3-16
(0261)
Expert
Vout Modulation Limit
Start Lvl
Sets the modulation factor that starts the output voltage limit operation when
C3-05 = 1
[Output Voltage Limit Selection = Enabled]
.
90.0%
(70.0 - 90.0%)
C3-17
(0262)
Expert
Vout Modulation Limit
Max Level
Sets the modulation factor used with
C3-18 [Output Voltage Limit Level]
for the output
voltage limit operation when
C3-05 = 1 [Output Voltage Limit Selection = Enabled]
.
100.0%
(85.0 - 100.0%)
C3-18
(0263)
Expert
Output Voltage Limit
Level
Sets the maximum drop width of the voltage reference when
C3-05 = 1 [Output Voltage
Limit Selection = Enabled]
.
90.0%
(50.0 - 100.0%)
C3-21
(033E)
RUN
Motor 2 Slip
Compensation Gain
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to
change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
•
E4-01 [Motor 2 Rated Current]
•
E4-02 [Motor 2 Rated Slip]
•
E4-03 [Motor 2 Rated No-Load Current]
Determined by E3-01
(0.0 - 2.5)
C3-22
(0241)
RUN
Motor 2 Slip Comp
Delay Time
Sets the slip compensation delay time for motor 2 when speed is unstable or when the
slip compensation response is too slow. Usually it is not necessary to change this
setting.
Determined by E3-01
(0 - 10000 ms)
C3-23
(0242)
Motor 2 Slip
Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor 2
rated slip.
200%
(0 - 250%)
C3-24
(0243)
Motor 2 Slip Comp
during Regen
Sets the slip compensation during regenerative operation function for motor 2.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
0
(0 - 2)
C3-29
(1B5D)
Expert
Slip Compensation Gain
@ Low Spd
Sets the gain for the slip compensation function in the low speed range. Usually it is not
necessary to change this setting.
0.0
(0.0 - 2.5)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...