d3: Jump Frequency
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
d3-01
(0294)
Jump Frequency 1
Sets the median value of the frequency band that the drive will avoid.
0.0 Hz
(Determined by A1-02)
d3-02
(0295)
Jump Frequency 2
Sets the median value of the frequency band that the drive will avoid.
0.0 Hz
(Determined by A1-02)
d3-03
(0296)
Jump Frequency 3
Sets the median value of the frequency band that the drive will avoid.
0.0 Hz
(Determined by A1-02)
d3-04
(0297)
Jump Frequency Width
Sets the width of the frequency band that the drive will avoid.
1.0 Hz
(Determined by A1-02)
◆
d4: Frequency Ref Up/Down & Hold
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
d4-01
(0298)
Freq Reference Hold
Selection
Sets the function that saves the frequency reference or the frequency bias (Up/Down 2)
after a Stop command or when de-energizing the drive.
Set
H1-xx [MFDI Function Selection]
to one of these values to enable this parameter:
•
A [Accel/Decel Ramp Hold]
•
10/11 [Up/Down Command]
•
75/76 [Up/Down 2 Command]
0 : Disabled
1 : Enabled
0
(0, 1)
d4-03
(02AA)
RUN
Up/Down 2 Bias Step
Frequency
Sets the bias that the Up/Down 2 function adds to or subtracts from the frequency
reference.
0.00 Hz
(0.00 - 99.99 Hz)
d4-04
(02AB)
RUN
Up/Down 2 Ramp
Selection
Sets the acceleration and deceleration times for the Up/Down 2 function to apply the
bias to the frequency reference.
0 : Use Selected Accel/Decel Time
1 : Use Accel/Decel Time 4
0
(0, 1)
d4-05
(02AC)
RUN
Up/Down 2 Bias Mode
Selection
Sets the function that saves the bias value to the drive when you open or close the two
Up/Down 2 Commands [H1-xx = 75, 76]
. Set
d4-03 [Up/Down 2 Bias Step Frequency]
= 0.00
before you set this parameter.
0 : Hold when Neither Up/Down Closed
1 : Reset when Neither / Both Closed
0
(0, 1)
d4-06
(02AD)
Frequency Ref Bias (Up/
Down 2)
Saves the bias value from the Up/Down 2 Command where the Maximum Output
Frequency is 100%.
Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the
maximum output frequency.
•
A1-02 ≠ 8 [EZOLV]
:
E1-04 [Maximum Output Frequency]
•
A1-02 = 8
:
E9-02 [Maximum Speed]
0.0%
(-99.9 - +100.0%)
d4-07
(02AE)
RUN
Analog Freq Ref
Fluctuate Limit
If the frequency reference changes for more than the level set to this parameter, then the
bias value will be held. The value is set as a percentage of the Maximum Output
Frequency.
Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the
maximum output frequency.
•
A1-02 ≠ 8 [EZOLV]
:
E1-04 [Maximum Output Frequency]
•
A1-02 = 8
:
E9-02 [Maximum Speed]
1.0%
(0.1 - 100.0%)
d4-08
(02AF)
RUN
Up/Down 2 Bias Upper
Limit
Sets the upper limit of the Up/Down 2 bias as a percentage of the Maximum Output
Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the
maximum output frequency.
•
A1-02 ≠ 8 [EZOLV]
:
E1-04 [Maximum Output Frequency]
•
A1-02 = 8
:
E9-02 [Maximum Speed]
100.0%
(0.0 - 100.0%)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...