d4-08: Up/Down 2 Bias Upper Limit
No.
(Hex.)
Name
Description
Default
(Range)
d4-08
(02AF)
RUN
Up/Down 2 Bias Upper
Limit
Sets the upper limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
100.0%
(0.0 - 100.0%)
The drive saves the set bias upper limit in
d4-06 [Frequency Ref Bias (Up/Down 2)]
. Set
d4-08
an applicable
value before you use the Up/Down 2 function.
Note:
When
d4-01 = 1 [Freq Reference Hold Selection = Enabled]
and
b1-01 = 0 [Frequency Reference Selection 1 = Keypad]
, the drive will
add the bias value to the frequency reference when it does not receive an Up/Down 2 command for 5 s. Then the drive will reset the
value to 0 at which time you can increase the bias to the limit set in
d4-08
again.
■
d4-09: Up/Down 2 Bias Lower Limit
No.
(Hex.)
Name
Description
Default
(Range)
d4-09
(02B0)
RUN
Up/Down 2 Bias Lower
Limit
Sets the lower limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
0.0%
(-99.9 - 0.0%)
The drive saves the set bias lower limit in
d4-06 [Frequency Ref Bias (Up/Down 2)]
. Set
d4-09
to an applicable
value before you use the Up/Down 2 function.
Note:
When
d4-01 = 1 [Freq Reference Hold Selection = Enabled]
and
b1-01 = 0 [Frequency Reference Selection 1 = Keypad]
, the drive will
add the bias value to the frequency reference when it does not receive an Up/Down 2 command for 5 s. Then the drive will reset the
value to 0.
If you increase the bias with the Up 2 command and
d4-09 = 0
, you cannot use a Down 2 command to decrease the frequency reference.
To decrease speed in this condition, set a negative lower limit in
d4-09
.
■
d4-10: Up/Down Freq Lower Limit Select
No.
(Hex.)
Name
Description
Default
(Range)
d4-10
(02B6)
Up/Down Freq Lower Limit
Select
Sets the lower frequency limit for the Up/Down function.
0
(0, 1)
0 : Greater of d2-02 or Analog
The higher value between
d2-02 [Frequency Reference Lower Limit]
and an analog input programmed for
Frequency Reference [H3-02, H3-10 = 0]
sets the lower frequency reference limit.
Note:
When you use
External Reference 1/2 Selection [H1-xx = 2]
to switch between the Up/Down function and an analog input as the
reference source, the analog value becomes the lower reference limit when the Up/Down command is active. Set
d4-10 = 1
to isolate the
Up/Down function and the analog input value.
1 : d2-02
You can only use
d2-02
to set the lower limit of the frequency reference.
■
d4-11: Bi-directional Output Selection
No.
(Hex.)
Name
Description
Default
(Range)
d4-11
(02B7)
Bi-directional Output
Selection
Sets the function that changes the frequency reference to a Bi-Directional internal frequency
reference.
0
(0, 1)
0 : Disabled
The drive will not change the frequency reference or PID output value to Bi-Directional internal frequency
reference.
When the frequency reference or PID output value is 0% to 100% of the maximum output frequency, the drive
runs the motor in the set direction.
1 : Enabled
Changes the frequency reference or PID output value to Bi-Directional output.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...