No.
Name
Unit
Motor Code (setting value of E5-01)
E5-03
PM Motor Rated Current
(FLA)
A
13.65
20.7
27.5
33.4
39.8
52.0
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
E5-05
PM Motor Resistance (ohms/
phase)
Ω
0.786
0.349
0.272
0.207
0.148
0.235
E5-06
PM d-axis Inductance (mH/
phase)
mH
16.49
13.17
10.30
8.72
6.81
5.4
E5-07
PM q-axis Inductance (mH/
phase)
mH
23.46
15.60
12.77
11.22
8.47
7.26
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad
520.0
481.5
498.8
509.5
503.9
561.7
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Output Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
L3-24
Motor Accel Time @ Rated
Torque
s
0.077
0.084
0.102
0.101
0.098
0.130
n5-02
Motor Inertia Acceleration
Time
s
0.077
0.084
0.102
0.101
0.098
0.130
n8-49
Heavy Load Id Current
%
-18.6
-12.5
-15.5
-17.9
-15.1
-16.8
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 11.13 SSR1 Series Motor Code Setting for Specification of 200 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
1302
1303
1305
1306
1308
130A
Voltage Class
V
200
200
200
200
200
200
Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
Motor Rotation Speed
min
-1
1450
1450
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
E5-03
PM Motor Rated Current
(FLA)
A
1.88
3.13
5.63
8.33
14.17
20.63
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
E5-05
PM Motor Resistance (ohms/
phase)
Ω
3.190
1.940
1.206
0.665
0.341
0.252
E5-06
PM d-axis Inductance (mH/
phase)
mH
32.15
26.12
14.72
12.27
8.27
6.49
E5-07
PM q-axis Inductance (mH/
phase)
mH
41.74
34.30
20.15
14.77
9.81
7.74
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad
264.3
269.6
284.3
287.1
284.5
298.0
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
L3-24
Motor Accel Time @ Rated
Torque
s
0.098
0.071
0.066
0.087
0.085
0.072
n5-02
Motor Inertia Acceleration
Time
s
0.098
0.071
0.066
0.087
0.085
0.072
n8-49
Heavy Load Id Current
%
-6.6
-10.9
-13.5
-9.0
-9.5
-10.1
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...