YASKAWA
SIEPC71061753A GA500 Technical Manual
399
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
n8-39
(0566)
PM Phase Compensation
Gain
Sets the low-pass filter shut-off frequency for high frequency injection.
Note:
•
Set
n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection]
or
n8-
57 = 1 [HFI Overlap Selection = Enabled]
to enable this parameter.
•
The drive automatically calculates this value when High Frequency Injection
Auto-Tuning completes successfully.
250 Hz
(0 - 1000 Hz)
n8-41
(0568)
Expert
HFI P Gain
Sets the response gain for the high frequency injection speed estimation.
2.5
(-10.0 - +10.0)
n8-42
(0569)
Expert
HFI I Time
Sets the integral time constant for the high frequency injection speed estimation.
Usually it is not necessary to change this setting.
0.10 s
(0.00 - 9.99 s)
n8-45
(0538)
Speed Feedback
Detection Gain
Sets the internal speed feedback detection reduction unit gain as a magnification value.
Usually it is not necessary to change this setting.
0.80
(0.00 - 10.00)
n8-47
(053A)
Pull-in Current Comp
Filter Time
Sets the time constant the drive uses to align the pull-in current reference value with the
actual current value. Usually it is not necessary to change this setting.
5.0 s
(0.0 - 100.0 s)
n8-48
(053B)
RUN
Pull-in/Light Load Id
Current
On the basis that parameter
E5-03 [Motor Rated Current (FLA)]
is the 100% value, this
parameter sets the d-axis current that flows to the motor during run at constant speed as
a percentage.
30%
(0 - 200%)
n8-49
(053C)
RUN
Expert
Heavy Load Id Current
Sets the d-axis current to that the drive will supply to the motor to run it at a constant
speed with a heavy load. Considers
E5-03 [PM Motor Rated Current (FLA)]
to be
100%. Usually it is not necessary to change this setting.
Determined by E5-01
(-200.0 - +200.0%)
n8-50
(053D)
Expert
Medium Load Iq Level
(High)
Sets the load current level at which heavy load control starts where
E5-03 [Motor Rated
Current (FLA)]
is 100%. Usually it is not necessary to change this setting.
80%
(50 - 255)
n8-51
(053E)
Pull-in Current @
Acceleration
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage
of the motor rated current.
Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the motor
rated current.
•
A1-02 = 5 [OLV/PM]
:
E5-03 [Motor Rated Current (FLA)]
•
A1-02 = 8 [EZOLV]
:
E9-06 [Motor Rated Current (FLA)]
Determined by A1-02
(0 - 200%)
n8-54
(056D)
Expert
Voltage Error
Compensation Time
Sets the time constant that the drive uses when adjusting for voltage errors.
1.00 s
(0.00 - 10.00 s)
n8-55
(056E)
Motor to Load Inertia
Ratio
Sets the ratio between motor inertia and machine inertia.
0 : Below 1:10
1 : Between 1:10 and 1:30
2 : Between 1:30 and 1:50
3 : Beyond 1:50
0
(0 - 3)
n8-57
(0574)
HFI Overlap Selection
Sets the function that detects motor speed with high frequency injection.
Note:
When you set
n8-57 = 1
, doHigh Frequency Injection Auto-Tuning.
0 : Disabled
1 : Enabled
0
(0, 1)
n8-62
(057D)
Expert
Output Voltage Limit
Level
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not
necessary to change this parameter.
200 V Class: 200.0 V,
400 V: 400.0 V
(200 V Class: 0.0 to
230.0 V, 400 V Class:
0.0 to 460.0 V)
n8-63
(057E)
Expert
Output Voltage Limit P
Gain
Sets the proportional gain for output voltage control. Usually it is not necessary to
change this setting.
1.00
(0.00 - 100.00)
n8-65
(065C)
Expert
Speed Fdbk Gain @ oV
Suppression
Sets the gain of internal speed feedback detection suppression while the overvoltage
suppression function is operating as a magnification value. Usually it is not necessary to
change this parameter.
1.50
(0.00 - 10.00)
n8-69
(065D)
Expert
Speed Observer Control
P Gain
Usually it is not necessary to change this setting. Sets the Proportional gain that the
drive uses for speed estimation.
1.00
(0.00 - 20.00)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...