E3-10: Motor 2 Minimum Output Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-10
(0320)
Motor 2 Minimum Output
Voltage
Sets the minimum output voltage for the motor 2 V/f pattern.
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
■
E3-11: Motor 2 Mid Point B Frequency
No.
(Hex.)
Name
Description
Default
(Range)
E3-11
(0345)
Expert
Motor 2 Mid Point B
Frequency
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this parameter.
0.0 Hz
(0.0 - E3-04)
Note:
•
Set this parameter to
0.0
to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
■
E3-12: Motor 2 Mid Point B Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-12
(0346)
Expert
Motor 2 Mid Point B
Voltage
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this parameter.
0.0 V
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to 510.0
V)
Note:
•
Set this parameter to
0.0
to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
■
E3-13: Motor 2 Base Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-13
(0347)
Expert
Motor 2 Base Voltage
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern for
the constant output range. Usually it is not necessary to change this parameter.
0.0 V
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to 510.0
V)
Note:
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
◆
E4: Motor 2 Parameters
E4 parameters [Motor 2 Parameters]
set induction motor data. To switch drive operation from one motor to a
different motor, configure motor 2.
Auto-Tuning automatically sets the
E4 parameters
to the best values for the application. If you cannot do Auto-
Tuning, set the
E4 parameters
manually.
Note:
E3-xx
and
E4-xx
are available when
H1-xx = 16 [MFDI Function Select = Motor 2 Selection]
.
■
E4-01: Motor 2 Rated Current
No.
(Hex.)
Name
Description
Default
(Range)
E4-01
(0321)
Motor 2 Rated Current
Sets the motor rated current for motor 2 in amps.
Determined by o2-04, C6-
01
(10% to 200% of the drive
rated current)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...